ERRORS shown b
y
SENSOR CONTROL BOARD (SCB) 22-aug-11
Display description problem Where to look / what to do
" " (nothing) = PCB standbymode/ sleepmode
1 All OK, ready to run Read softwareversion of all system
E25 No response main drive. (via CAN) Check Flatcable / Replace Main Board press lowest button on SCB
E26 Fail Safetyline test Main board Replace Main Board
Display will show 'd…L…C'
E30 No response level board. (via CAN) Check Flatcable / Replace Level Board
d… = version mainboard (drive)
E31 Fail Safetyline test Level board Replace Level Board
L… = version Leveldrive
E32 Fail Selftest Level board. Critical switch safetyline / Replace Level Board
C…= version sensor Control board
E33 * Overload LevelPCB / Levelmotor Long time high load. Continues heavy load out middle of outputshaft / Replace Level Board
E34 *
High / low supply voltage
{In software before version L27, this was only high supply voltage}
voltage fault on Level or Main board (Main board should respond earlier)
E35 Locked rotor / encoder fault Level motor Check wiring encoder / motor / Replace Level Board
E36 Motor direction error Critical switch safetyline / Check connection Level Motor
E37 Gate supply voltage missing, SLA and/or SLB not active (Tilt sensor?) Critical switch safetyline / Replace Level Board Calibrate chair and liftsensor
E38 *
High impuls current (overcurrent) {In softw. before version L27,this was low supply volt error}
Blocking of motor / Check wiring encoder Adjust seat horizontal. (by handwind)
press both buttons on SCB
E40 PCB error Sensor control Board Replace Sensor Control Board => calibate sensors after replacement display will show blinking 'h'
E41 Liftsensor Fault 1 (ADC) Replace Sensor Control Board => calibate sensors after replacement Hold buttons until blinking 'h' stops.
E42 Liftsensor Fault 2 (V) Replace Sensor Control Board => calibate sensors after replacement When 'h' is continue visible release buttons
E43
Liftsensor Fault 3 ()
Replace Sensor Control Board => calibate sensors after replacement Sensors are calibrated.
E44 Checksum error (Configs) Replace Sensor Control Board => calibate sensors after replacement
E45 System never has been calibrated. (factory default) Calibrate sensors
E50 Chairsensor outside range -3,5 or +3,5 degrees First check and set angle of Chairframe, do restart, and read 'new' error / or sensor not correctly calibrated
E51 Chairsensor Fault 1 (ADC) Replace Chairsensor => calibate sensors after replacement / check wiring Tiltsensor
E52 Chairsensor Fault 2 (V gyro) Replace Chairsensor => calibate sensors after replacement Set dynamic
E53
Chairsensor Fault 3 (V x/y) Replace Chairsensor => calibate sensors after replacement push highest button.
E54
Chairsensor Fault 4 ()
Replace Chairsensor => calibate sensors after replacement / check encodercable/connector While pressing highest button, press lowest
button 3 times.
(Then release highest button)
E60
Tilt sensor activated (outside -5 or +5deg )
Dual Safety line A (SLA) and B (SLB) not intact.
Tiltsensor activated / Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot OFF at display is normal dynamics
E61 Dual Safety line A (SLA) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt Dot ON is lower dynamic
E62 Dual Safety line B (SLB) not intact. Problem wiring tiltsensor or flatcable / PCB fault LEVEL / SCB / Tilt
E63
Fault in test Dualsafety-line (Given when fault is not E26/E31/E60/E61 or E62) [ NOTE * = no fast beep ]
ERRORS shown b
y
LEVEL BOARD
LED's description problem
LED 1 (YELLOW) Shows CPU status 0,5 Hz = OK / OFF = PCB not ON / ON = error
LED 2 (RED) Shows Status Dual Safetyline (output filter)
OFF Safety line filter A & B on
5Hz Safety line filter A off , B on
5Hz
1sON/1sOFF
Safety line filter A on , B off
ON Safety line filer A & B off
LED 3 (GREEN)
OFF / 0,5 Hz OK Motor control not active = off / Motor control active = 0,5 Hz
ON
Low / High supply voltage error / Motor direction error / Fail Selftest Level drive / Gate supply voltage missing (SCB for detail info)
5Hz 1sON/1sOFF
Locked rotor / encoder fault Level motor
5Hz Overcurrent/ Overload Level motor
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Otolift One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Otolift One in the language / languages: English as an attachment in your email.

The manual is 4,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info