668497
42
Zoom out
Zoom in
Previous page
1/51
Next page
ERRORS shown by MAIN BOARD 22-aug-11
Display description problem Where to look on MAIN PCB status OK
" " (nothing) = PCB stanbymode
0 Switch armrest is in OFF position X2b pin1, 2 NC
1 Switch armrest is in ON position (main safety-line is OK)
2 Swivelseat-switch is operated (3 options in case of powered rotating seat) X2c pin 1,2 NC
3 Extracontact is not connected (via jumpers) X7 pin 3,4 and 5,6 NC
4 Current x10-3 is higher then 100 mA X10-3 (should not be connected) (when displayed at ONE tube lift exchange PCB)
5 Lift is controlled on 2 places X2a pin1,3 or X3a pin 2,3 or X2a pin 3,4 or X3a pin 5,6 all NO
6 Lift did not charge for 1 or 8 hours depending of dipswitch 3 X10 pin 1,2 (pin 1 = voltage, pin 2 is (chassis)ground) 20 ~30Vdc
7 Lift came out of sleepmode / batterie connected and not controlled yet
A Safety-drive unit right is operated X4 pin 1,2 NC
b Safety-drive unit left is operated X4 pin 3,4 NC
C Safety-footrest right is operated X5 pin 1,2 NC
d Safety-footrest left is operated X5 pin 3,4 NC
E Safety-frame right is operated (normally jumpered in 1-tube lift) X6 pin 1,2 NC
F Safety-frame unit left is operated (normally jumpered in 1-tube lift) X6 pin 3,4 NC
g safety endswitch is operated while lift is on opposite endpoint X3a pin 1,2 at left endpoint or X3a pin 3,4 at right endpoint NC
1
1
Safety endswitch right is operated X3a pin 1,2 NC
11
Safety endswitch left is operated X3a pin 3,4
H High-load "overcurrent mainmotor" blokking/friction or simply too much weight
L Low batterie-voltage BATT + and BATT - 22 <=> 29V
t Temperature PCB to high
P Rotation monitor unit does not function correctl
y
X9a
p
in 1,2 IR-LED, X9a
p
in 3,4 switc
h
volta
g
e
p
in 3,4 alternatin
g
when movemen
t
y
p, , p,
gp , g
E01 too high voltage on X10-1. (wiringfault transformer/chargepoint) X10 pin 1,2 (pin 1 = voltage, pin 2 is (chassis)ground)
E02 overvoltage batteries exchange PCB (charging circuitry of measurement defect)
E03 relay-error exchange PCB
E04 other voltages in safety-line Main PCB
Connection of voltages to X3b, X9b, X2b, X2c or X7
E05 interconnection between safetyline left and right Connection between X3,X4,X5,X6 pin 1 or 2 to pin 3or 4
E06 MAIN PCB defect (safetyline left or right are active when not controlled) exchange PCB
E07 MAIN PCB defect (safetyline left or right will not active when controlled) exchange PCB
E08 SMD fuse, contact catch (osg) or limit-switch not active
X9b 1 led off, X3b 2 led off (jumper), fuse or conection Bypass 3 LED off
E09 Contacts on X7 do not work synchronously. X7 pin 3,4 and 5,6 (should be both jumpered)
E11 Bypass is connected and activated by hold to run.
E12 Batteries will not reach max voltage after 21 hours of charging
E13 * 10 times overcurrent on output x10-3
E13 is stored directly (after 1 time overcuurent x10-3)
E14 Internal defect PCB. exchange PCB
E15
Relay will not become active
(resistance in safetyline, Tiltsensor was active, relay defect ?)
E16 Wiring brake Main motor not connected (when no fault reported by SCB) Check fault SCB (when NO fault => X1 brake NOT connected? Or ...Critical switch safetyline / Replace Main Board )
E17
Relay will not become active
(resistance in safetyline, Tiltsensor was active, relay defect ?)
E18 * Motorposition fault When seen multiple times or when this error prevents movement exchange PCB
E20 Wrong dipswitch setting Main PCB Dipswitch 7 + 8 on, and jumper ON,
E97 Lift stopt by Sensorcontrol PCB (Check display on Sensorcontrol PCB) no beep
E98 Error set by Sensorcontrol PCB (Check display on Sensorcontrol PCB) fast beep
[ NOTE * = no fast beep ]
E99 * No responce of sensorcontrol PCB Sensor control board in off state
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Otolift One at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Otolift One in the language / languages: English as an attachment in your email.

The manual is 4,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info