587086
13
Zoom out
Zoom in
Previous page
1/17
Next page
11
EN
To select the wind speed unit:
Press UNIT (at the bottom of the base station) to switch
between:
Metres per second (m / s)
Kilometers per hour (kph)
Miles per hour (mph)
Knots (knots)
The wind level is shown by a series of icons:
ICON LEVEL DESCRIPTION
N/A <2 mph (<4km/h)
Light 2-8 mph (3~13 km/h)
Moderate 9-25 mph (~14-41 km/h)
Strong 26-54 mph (~42-87 km/h)
Storm >55 mph (>88 km/h)
To display the AVERAGE and GUST wind:
1. Press SELECT to navigate to the Wind Speed and
Wind Direction Area. will show next to the Area.
2. Press MODE to toggle between AVERAGE and GUST
wind readings.
To display the maximum speed and direction for
gust wind:
In the Wind Speed and Wind Direction Area, press
MEMORY / ON / OFF to toggle between wind speed
/ MAX GUST wind readings. The timestamp is displayed
accordingly in the Clock Area.
To clear the memories and timestamp for the wind
readings:
In the Wind Speed and Wind Direction Area, press and
hold MEMORY / ON / OFF to clear the readings.
To change the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press
and hold
ALARM to enter the high gust wind alarm
setting.
2. Rotate the dial left or right to set the desired values.
3. Press
ALARM to confirm the settings.
To activate / deactivate the high gust wind speed alarm:
1. In the Wind Speed and Wind Direction Area, press
ALARM repeatedly to select the desired alarm.
2. Press MEMORY /
ON / OFF to activate or
deactivate the alarm.
UVI / BAROMETER / RAINFALL
The weather station works with one UV sensor and
one rain gauge. The station is capable of storing and
displaying the hourly history data for the last 10 hours
of UV index, and 24 hours of rainfall and barometric
pressure readings.
UVI BAROMETER RAINFALL
The bar chart display shows the current and historical
data for the UV index, barometric pressure and rainfall
readings.
To view the UV / Barometer / Rainfall readings:
1. Press
SELECT to navigate to the UV / Barometer /
Rainfall Area. will show next to the Area.
2. Press MODE to toggle between UVI / Barometer /
Rainfall readings. The corresponding icon will appear:
UVI BAROMETER RAINFALL
3. Rotate the dial left or right to view the historical data
for the selected area. The corresponding historical
readings are showing.
NOTE The number shown in the HR icon indicates how
long ago each measurement was taken (e.g. 2 hours ago,
3 hours ago, etc.).
To select the measurement unit for the barometer or
rainfall readings:
In the UV / Barometer / Rainfall Area, press UNIT (at the
bottom of the base station) to switch between:
Barometer: Millimeters of mercury (mmHg), inches
of mercury (
inHg), millibars per hectopascal (mb /
hpa).
Rainfall: Millimeters (mm), inches (in), inches per
hour (in / hr) or millimeters per hour (mm / hr).
UV INDEX
The UV index levels are as follows:
UV INDEX DANGER LEVEL ICON
0-2 Low
3-5 Moderate
6-7 High
8-10 Very high
11 and above Extremely high
To change the high UV alarm:
1. In the UV / Barometer / Rainfall Area and UVI reading
display. Press and hold
ALARM to enter the high UV
alarm setting.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific WMR100NA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific WMR100NA in the language / languages: English as an attachment in your email.

The manual is 6,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific WMR100NA

Oregon Scientific WMR100NA User Manual - German - 18 pages

Oregon Scientific WMR100NA User Manual - Dutch - 17 pages

Oregon Scientific WMR100NA User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info