4
cally which is indicated by the appearance of the [ ] symbol.
To disable this function, press the DOWN button in the Pre Alarm
mode. The [ ] symbol will disappear to indicate such disable.
The pre-alarm will operate during the selected time interval before
the daily alarm time. For example, if the daily alarm is set to go off
at 7:00 am and the pre-alarm operating time interval is set to 45
minutes, the pre-alarm will start to operate at 6:15 am (45 minutes
before 7:00 am).
During the pre-alarm operating period, if the temperature recorded
at Channel 1 remote sensor falls to or below 2.0ºC, the pre-alarm
will be triggered. The Pre-Alarm icon will flash and the backlight
will be turned on for 5 seconds. An alarm sound will also go off for
2 minutes as that of the daily alarm and the snooze function will
also be activated if the SNOOZE/LIGHT button is pressed.
Note: The daily alarm will NOT function until the next day if the
pre-alarm has been triggered beforehand. Deactivation of the
alarm function will disable the pre-alarm feature automatically.
HOW TO CHECK INDOOR AND OUTDOOR-
REMOTE TEMPERATURES & HUMIDITIES
To display indoor temperatures and humidities, press the CHAN-
NEL button until the [ ] indicator lights up.
To display outdoor-remote temperatures and humidities, press the
CHANNEL button to scroll through the readings from up to 3
remote sensors.
The temperature can be shown in Centigrade (°C) or Fahrenheit
(°F). It is selected on the °C/°F slide switch. Slide the switch to °C
for Centigrade or °F for Fahrenheit.
If the readings go above or below the specified range, the display
will show flashing “HHH” or “LLL”.
CHANNEL SCAN FUNCTION
Press and hold CHANNEL button for 3 seconds to enter channel
scan function. The readings of each channel will be displayed one
by one for 4 seconds automatically. Press any key can stop the scan
function.
NOTE ON REMOTE TEMPERATURE
& HUMIDITY
Once batteries are in place for the remote unit, it will start transmit-
ting samplings at 39-43-second intervals.
If no signals are received when the remote temperature and humid-
ity is selected, blanks will be displayed. Press and hold the CHAN-
NEL button to enforce a search. This is useful in synchronizing the
transmission and reception of the remote and main units.
If that fails, check if the remote unit is still in place. Make sure the
transmission is within range and path is clear of obstacles and
interference.
Repeat this procedure whenever you find discrepancies between
the reading shown on the main unit and the remote unit.
Press MODE. The E, D, F, I or S language indicator will flash.
Use the UP or DOWN button to select E for English, I for Italian,
D for German, F for French or S for Spanish.
The display language of the day-of-the-week is selected in the
calendar setting procedure. The foreign languages and their mean-
ings are as follows:
Day-of-the-week
Language
Monday Tuesday Wed. Thursday Friday Saturday Sunday
English
German
French
Italian
Spanish
Press MODE to confirm and exit.
HOW TO SET AND ACTIVATE
THE DAILY ALARM
When the daily alarm time is displayed, press and hold ALARM for
three seconds.
Enter the value for the hour digits by the UP or DOWN button.
Press ALARM to confirm and go to the minute digits. Enter the
value and press ALARM to confirm.
The alarm is automatically activated. To deactivate it, press ALARM
once to display the alarm time. Then use the UP or DOWN button
to toggle its status.
ALARM AND SNOOZE FUNCTION
When the alarm is active, it will go off at the set time. The display
will light up for five seconds with the ALARM ON icon flashing.
The crescendo function allows the alarm to start off gently and step
up its intensity in three steps. Without interruption, the alarm will
go off for 2 minutes.
To stop the alarm, press any button. If the SNOOZE/LIGHT
button is pressed, the SNOOZE function will be triggered. The
alarm will stop and the bell icon blinks for about eight minutes
before going off again.
PRE-ALARM FUNCTION FOR
CHANNEL 1 REMOTE SENSOR
The alarm function also has a pre-alarm feature which can alert the
user before the preset alarm time when weather condition changes.
This pre-alarm function applies to Channel 1 Remote Sensor only.
To enable this function, first activate the alarm function. Then enter
the Pre-Alarm mode by pressing the ALARM button twice. The
“Pre-Al” icon will be displayed. Press and hold the ALARM button
for 3 seconds to set the operating time interval for this pre-alarm
function. Use the UP or DOWN button to select from the 4 time-
intervals: 15, 30, 45 or 60 minutes. Press the ALARM button to
confirm and exit. The pre-alarm function will be enabled automati-
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oregon Scientific BAR938HG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oregon Scientific BAR938HG in the language / languages: English as an attachment in your email.

The manual is 0,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Oregon Scientific BAR938HG

Oregon Scientific BAR938HG User Manual - German - 8 pages

Oregon Scientific BAR938HG User Manual - Dutch - 8 pages

Oregon Scientific BAR938HG User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info