To monitor the length of time (number of hours) the circuit has
been active (C1 ON), selecting the EXTRAS COUNTER
option displays the number of hours to 4 figures (up to 9999
hours). This counter is not zeroed when the device is reset.
In normal operating mode, press “OK“ and use the and
keys to find EXTRAS COUNTER. Pressing “OK“ again brings
up COUNTER C1 on display and the number of hours the
circuit has been on to four figures.
Press “C“ repeatedly to go back to normal operation.
If you wish to erase the counter, from the display showing the
number of "ON" hours, press “OK“ and CONT C1 CLEAR
will be displayed on display. Press “OK“ again and the display
will show CLEAR C1 YES. Use and to choose between
YES and NO and confirm pressing “OK“. Press the “C“ key
repeatedly to go back to normal operating mode.
12 (AM – PM) or 24-HOUR TIME MODE
You can choose between the time being displayed in AM : PM
or 24-hour format. In normal operating mode, press “OK“ and
use and to find EXTRAS 12/24H. From this menu,
choose 12H or 24H and confirm with “OK“. Press the “C“ key
repeatedly to return to normal operating mode. If the 12h
function has been chosen, AM or PM will be shown on
display, depending on the current time.
CYCLE PROGRAMMING
A cycle is a sequence of repetitive switches.
Each programmed cycle takes up two memory spaces
(PROG X and PROG X+1). Before programming, check that
the next memory program is free, optión CYCLE will not them
be available. CYCLE programs are not permited in memory
program 50.
Go into the PROGRAM menu and press “OK.“ Use the and
keys to choose a program (PROG XX), press “OK“ again
and PROG PROGRAM will be displayed. Confirm with “OK“
and C1:ON will be displayed. Select CYCLE, press “OK,“ and
you will see DAY BEG MON: YES (to allow you to select the
starting day for the cycle). If you want it to begin on Monday,
press “OK,“ otherwise use the and keys until DAY BEG
MON: NO appears on the display. Press “OK“ to accept and
repeat the operation for the other days of the week, selecting
and confirming them in the same way.
When you have chosen the days, you need to select the start
time for the cycle, beginning with the hour. Use the and
keys to enter the hour and confirm with “OK.“ Enter the cycle
start minutes in the same way, and when you confirm “ OK “,
DAY END MON: YES (to allow you to select the last day for
the cycle) will be displayed. Repeat the same procedure to
enter the days, hours and minutes for conclusion of the cycle.
Next, the cycle connection time (TIME ON ) needs to be
programmed. Enter the figures for hours and minutes
(maximum 8 hours 59 minutes.- minimum 0 hour 1 minute)
and then the cycle disconnection time (TIME OFF) in hours
and minutes (maximum 8 hours 59 minutes.- minimum 0 hour
1 minute). ( See exemple )
Do not program averlaped cycles, as during the execution of
one cycle, the overlaped cycle will not start. Cycles are shown
in chronogram as ON from begining to the end.
TECHNICAL FEATURES
Power supply: As indicated on the device
Switching capacity: 16 (4) A/250V
Maximum recomended loads:
Incandescent lamps: 3000 W
Fluorescent lamps 1200 W
Low voltage halogen lamps 2000 VA
Halogens (230 V) 3000 W
Low-consumption lamps 600 W
Downlights 400 W
Leds 600 W
Contact type and material: Changeover AgSnO2
Power consumption: 6 VA 1 circuit (approx.1W)
Number of programs: 50
Type of programs: ON OFF
PULSE (1 to 59 seconds)
CYCLES (from 1 minute
to 8 hours 59 minutes, in
ON or OFF times)
Switching accuracy: Better than 1 second
Operating accuracy: ± 1s/day at 23ºC
Reserve battery: 5 years. (Lithium Battery)
Working temperature: -10 ºC to +45 ºC
Protection type: IP 20 according to
EN 60529
IP 51 (MINI LOG) on
surface mounting.
Protection class: II (MINI LOG) according to
EN 60335 when mounting
as intended
Pollution situation: Normal
DIMENSIONS
06/2011 A016.36.51418
ORBIS TECNOLOGÍA ELÉCTRICA S.A.
Lérida, 61 Tel.: + 34 91 567 22 77
E-28020 MADRID Fax + 34 91 571 40 06
E-mail: info@orbis.es
http://www.orbis.es
1h10min. ON
Time ON
Day end
Time ON
Monday 9:00h
Begin day
2h20min. OFF
Time OFF
Friday 13:00h
LANGUAGE SELECTION
OK
IDIOMA
ESPAÑOL
LANGUAGE
ENGLISH
MA 04  01 - 00
C1: OFF
23 : 48 : 07 ?
COK
>3 s
ó
date
year
01 - 01 - 00
CLOCK SETTING
OK
OK OK OK
OK OK C
date
year
01 - 00 - 00
date
MonTH
01 - 01 - 00
MENU
MANUAL
MENU
PROGRAM
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
MENU
DATE
MENU
PROGRAM
TIME
MINUTE
23 : 48 : 00
TIME
HOUR
23 : 00 : 00
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
DATE
DAY
04 - 01 - 00
ó
ó
OK
OK OK
OK
OK
.........
OK C C
PROG 02:
minutE
C1 : ON
09 : 30 : 00
2
PROG 02:
hoUR
C1 : ON
11 : 00 : 00
2
PROG 02:
SU: no
C1 : ON
00 : 00 : 00
2
MENU
MANUAL
program
prog 03:
C1 : ON
- - : - - : - -
1 2 3 4 5 6 7
PROG 02:
WE: YES
C1 : ON C2:
00 : 00 : 00
2
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
2
PROG 02:
WE: NO
C1 : ON
00 : 00 : 00
2
ó
ó
ó
OK OK
OK
OK
OK
OK
OK
OK
OK
OK OK
OK OK
OK
PROG 01:
OFF
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
TU: YES
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
TU: no
C1 : ON
00 : 00 : 00
1 3 4 5 6 7
PROG 01:
minutE
C1 : ON
09 : 10 : 00
1
PROG 01:
HoUR
C1 : ON
09 : 00 : 00
1
PROG 01:
SU: no
C1 : ON C2:
00 :
00
:
00
PROG 01:
WE: YES
C1 : ON
00 : 00 : 00
1 3 4 5 6 7
PROG 01:
minutE
C1 : ON
09 : 10 : 00
1
PROG 02:
program
C1 : ON
- - : - - : - -
1 2 3 4 5 6 7
program
prog 02:
C1 : ON
- - : - - : - -
1 2 3 4 5 6 7
PROG 02:
C1 : oFF
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
PROG 02:
C1 : ON
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
PROG 02:
C1 : CYCLE
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
PROG 01:
C1 : ON
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
C1 : CYCLE
PROG 01:
C1 : PULSE
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
MO: YES
C1 : ON
00 : 00 : 00
2 3 4 5 6 7
PROG 01:
MO: no
C1 : ON
00 : 00 : 00
2 3 4 5 6 7
MENU
PROGRAM
234567
PROGRAM
PROG 01:
C1 :
- - : - - : - -
PROG 01:
PROGRAM
C1 :
- - : - - : - -
PROG 02:
C1 : PULSE
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
PROG 02:
MO: YES
C1 : ON
00 : 00 : 00
PROG 02:
MO: no
C1 : ON
00 : 00 : 00
2 3 4 5 6 7
PROG 02:
TU: YES
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
PROG 02:
TU: no
C1 : ON
00 : 00 : 00
1 3 4 5 6 7
PROGRAMMING ON: Monday 09:10 OFF: Tuesday 11:30
OK
ó
ó
ó
ó
ó
OK
ó
ó
ó
OK OK
OK OK
OK OK
C,C,C,......
DAY END
HOUR
C1 :
18 : 00 : 00
5
T
IME ON
HOUR
C1 :
02 : 00 : 00
5
T
IME OFF
HOUR
C1 :
05 : 00 : 00
5
T
IME OFF
hora
C1 :
00 : 00 : 00
5
T
IME ON
MINUTE
C1 :
02 : 00 : 00
5
PROGRAM
PROG: O3
T
IME OFF
MINUTE
C1 :
05 : 00 : 00
5
DAY END
MINUTE
C1 : ON
18 : 00 : 00
5
T
IME ON
HOUR
C1 :
00 : 00 : 00
5
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
2
ó
ó
OK OK OK
OK
OK
OK
OK
OK
OK
....................
OK
OK
OK
..........
PROG 01:
C1 : OFF
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
DAY BEG
tu: yes
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
DAY BEG
tu: no
C1 : ON
00 : 00 : 00
1 3 4 5 6 7
DAY BEG
HOUR
C1 :
09 : O0 : 00
1
DAY BEG
hoUR
C1 :
00 : 00 : 00
1
DAY BEG
SU: no
C1 :
00 : 00 : 00
1
DAY BEG
TU: NO
C1 :
00 : 00 : 00
1 4 5 6 7
DAY BEG:
C1 :
09 : 00 : 00
1
DAY END
MO: YES
C1 : C2:
09 : 00 : 00
1 2 3 4 5 6 7
DAY END
FR: YES
C1 : C2:
09 : 00 : 00
5 6 7
DAY END
FR: NO
C1 :
09 : 00 : 00
5 6 7
TU 04  01 - 00
C1: OFF
23 : 48 : 07
?
PROG 01:
C1 : ON
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
C1 : PULSE
C1 : ON C2:
00 : 00 : 00
1 2 3 4 5 6 7
PROG 01:
C1 : CYCLE
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
Day BEG
mo: yes
C1 : ON
00 : 00 : 00
mo: no
C1 : ON
00 : 00 : 00
1 2 3 4 5 6 7
MENU
PROGRAM
PROGRAM
PROG 01:
C1 : C2: :
- - : - - : - -
PROG 01:
PROGRAM
C1 :
- -: - - : - -
DAY END
SU: YES
C1 : C2:
09 : 00 : 00
5 7
DAY END
SU: no
C1 :
09 : 00 : 00
5
DAY END
HOUR
C1 :
00 : 00 : 00
PROGRAM
PROG 02:
C1 : C2: :
- - : - - : - -
PROGRAM
PROG 03:
C1 :
- - : - - : - -
DAY END
MO: NO
C1 :
09 : 00 : 00
2 3 4 5 6 7
PROGRAMMING CYCLE. START DAY: Monday 09:00. END DAY: Friday 18:00. ON: 2h OFF: 5h
ó
OK
ó
........
ó
ó
ó
.........
ó
ó
ó
.......
ó
....................
minutE
OK
Day BEG
OK
5
60
60
35
7
46
7
21
1.5
Ø62
9 42 9
54
54
R1.5
Terminali
Faston 6,3
DIN 46248
MODUL LOG
54
R1.5
6672
72
38 429 9
21
54
MINI T LOG
66
47 66
103
MINI LOG
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Orbis MODUL LOG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Orbis MODUL LOG in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info