549536
32
Zoom out
Zoom in
Previous page
1/38
Next page
30
Specifications
Factory Default Settings
Factory default settings and backup are as shown below.
Backup
: Setting is retained even if the power is interrupted.
: Reverts to factory default setting if the power is turned off.
Technical Specifications: HBP-1300
Main unit
Power supply
Setting Pressure Value Settings Factory Setting Backup
Initial Inflation Pressure Value AUTO, 220, 250, 280 AUTO
Auscultation Mode ON, OFF OFF
Auto Power Off 5 min, 10 min 5 min
Measurement Parameter NIBP, PR
Dimension Main unit: 123 x 201 x 99 (mm) 4.84 x 7.91 x 3.90 (inch) (W x H x D)
AC adapter: 46 x 66 x 37 (mm) 1.81 x 2.60 x 1.46 (inch) (W x H x D)
Battery: 54 x 43.5 x 15.4 (mm) 2.13 x 1.71 x 0.61 (inch) (W x H x D)
Weight
Main unit: Approx. 0.52 kg (not including accessories and options)
AC adapter: Approx. 0.2 kg
Battery: Approx. 0.1 kg
Display 7 segment LCD
Protection Class
Class II (AC Adapter)
Internal powered equipment (when operating with battery only)
Degree of Protection
Type BF
MDD Classification Class II a
AC adapter Input voltage range: AC 100 V to 240 V
Frequency: 50/60 Hz
Output voltage range: DC 6 V ±5%
Rated output current: 1.6 A
Rechargeable battery Type: 3.6 V, 1900 mAh
Number of operation cycles when fully charged: 300
Measurement conditions
New battery fully charged
Ambient temperature of 23°C (73.4°F)
Using M-size cuff
SYS 120 / DIA 80 / PR 60 (Inflation setting: AUTO)
One 5-minute cycle consisting of “cuff measurement time + wait time
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron HBP-1300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron HBP-1300 in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Omron HBP-1300

Omron HBP-1300 User Manual - German - 38 pages

Omron HBP-1300 User Manual - Dutch - 38 pages

Omron HBP-1300 User Manual - French - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info