System Settings
The system settings are divided into two modes, “Menu Mode” and “Utility Mode”.
Menu Mode
“Menu Mode” allows you to configure the “Initial Inflation Pressure Value” and “Auscultation Mode” settings.
1. Press the [MODE] button.
The “Initial Inflation Pressure Value” setting screen appears.
2. Press the [ ] or [ ] button to change the setting.
Press the [ ] button to change the setting in the order “280”, “250”, “220”, “AUTO”, “280”...
Press the [ ] button to change the setting in the order “220”, “250”, “280”, “AUTO”, “220”...
When the “Initial Inflation Pressure Value” is set, inflation takes place at a fixed speed to the set
value and thus is quicker.
“AUTO” estimates the systolic blood pressure during inflation and automatically inflates the cuff to a
suitable value.
When using “220”, “250”, or “280” mmHg, select the value that is 30 to 40 mmHg higher than the
estimated systolic blood pressure.
3. When you have completed the “Initial Inflation Pressure Value” setting,
press the [MODE] button.
The “Auscultation Mode” settings screen appears.
4. Press the [ ] or [ ] button to set to “ON” or “OFF”.
When set to “ON”, SYS and DIA can be recorded using auscultation measurement.
For information on auscultation measurement, see page 22.
5. When you have completed the “Auscultation Mode” setting, press the
[MODE] button.
“0” appears.
To start blood pressure measurement, press the [START/STOP] button.
Note:
The body movement detection function is disabled while “Auscultation Mode” is in use.
If the power is turned off, the settings revert to the factory settings.
“Initial Inflation Pressure Value” changes to “AUTO”, and “Auscultation Mode” changes to “OFF”.
Initial Inflation
Pressure Value
Auscultation Mode
“ON” or “OFF”
appears.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Omron HBP-1300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Omron HBP-1300 in the language / languages: English as an attachment in your email.

The manual is 0,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Omron HBP-1300

Omron HBP-1300 User Manual - German - 38 pages

Omron HBP-1300 User Manual - Dutch - 38 pages

Omron HBP-1300 User Manual - French - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info