Please read this instruction manual carefully before use and for further information on the
individual functions.
Danger:
• Never use this unit in combination with the following medical electronic devices.
(1) Medical electronic implants such as pacemakers.
(2) Electronic life support systems such as an articial heart/lung.
(3) Portable electronic medical devices such as electrocardiograph.
• This unit may cause the above-mentioned medical electronic devices to malfunction, posing a
considerable health risk to users of these devices.
Warning:
• Never start weight reduction or exercise therapy solely based on your own judgement. Be sure
to follow the instructions of a doctor or specialist.
• Do not use the unit on tiles or other surfaces that may be slippery, such as a wet oor.
• Do not subject the unit to strong shocks, such as vibrating or dropping the unit on the oor.
• Do not jump or bounce on the unit.
• Do not use this unit after taking a bath, or when your body, hands, or feet are wet.
• Do not step on the edge of the unit.
• Do not let a physically handicapped person use this unit without any accompanied assistance.
Use a handrail or so when stepping on the unit.
Caution:
• This unit is intended for home use only. It is not intended for professional use in hospitals or
other medical facilities.
• This unit does not support the standards required for professional use.
• Stand on the unit bare-footed.
•
Do not use a cellular phone near the unit.
•
Do not disassemble, repair
, or remodel the unit.
• Do not use batteries not specied for this unit. Do not insert the batteries with the polarities in
the wrong direction.
• Replace worn batteries with new ones immediately.
• Remove the batteries from this unit when you are not going to use it for a long period of time
(approximately three months or more).
• Do not use batteries of a different kind together.
• Do not use new and worn batteries together.
• Keep this unit out of the reach of young children.
General Advice:
• Do not place this unit on cushioned oor surface such as on a carpet or a mat. Correct
measurement may not be possible.
• Do not step on the operation buttons. Doing so may cause malfunction.
• Do not place this unit in highly humid environment, where water may splash, under direct
sunshine, in a place where the air conditioner blows directly, or near re.
• Do not use this unit for purposes other than measuring body weight and body fat percentage.
• Disposal of this product and used batteries should be carried out in accordance with the
national regulations for the disposal of electronic products.
• Always keep the unit clean before use.
• Clean the scale before using the unit with people who have a skin or foot disease.
• Do not wash the unit with water.
• Do not wipe the unit with benzene or paint thinner.
• When cleaning the unit, take care not to touch the buttons and change or delete the personal data.
• If storing the unit in a vertical position, always secure it so that it will not fall over.
• Do not store the unit in the following conditions:
- Where water may get in.
- Extreme high temperature and humidity, direct sunshine, and dusty places.
- Where there will be sudden shock or vibration.
-
In storage places of chemicals or where corrosive gas is present.
•
Do not place objects on the unit or store it upside-down.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’
s and mobile (cellular) telephones,
medical devices in use may be susceptible to electromagnetic interference from other devices.
Electromagnetic interference may result in incorrect operation of the medical device and create a
potentially unsafe situation.
Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to
prevent unsafe product situations, the EN60601-1-2:2007 standard has been implemented. This
standard denes the levels of immunity to electromagnetic interferences as well as maximum
levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007
standard for both immunity and emissions.Nevertheless, special precautions need to be observed:
● Do not use mobile (cellular) telephones and other devices, which generate strong electrical or
electromagnetic elds, near the medical device. This may result in incorrect operation of the unit
and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m.
Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is avail-able at OMRON
HEALTHCARE EUROPE at the address mentioned in this instruction manual.Documentation is
also available at www.omron-healthcare.com.
Correct Disposal of This Product(Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be
disposed of, with other household wastes at the end of its working life. To prevent pos-
sible harm to the environment or human health from uncontrolled waste disposal, please
separate this product from other types of wastes and recycle it responsibly to promote
the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their
local government ofce, for details of where and how they can return this item for environmentally
safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product should not be mixed with other commercial wastes for disposal.
Technical Data
Product description Body Composition Monitor
Product name BF212
Model HBF-212-EW
Display Body Weight: 2 to 150 kg with an increment of 0.1 kg / 4.4 to 330.0 lb with an increment of 0.2 lb / 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb
Body Fat percentage: 5.0 to 60.0% with an increment of 0.1%
• The age range for the BMI, BMI classication and Body Fat percentage is 10 to 80 years.
Set Items Personal data information: The following information for up to 4 people can be stored.
Height: 100.0 to 199.5 cm , 3'4" to 6'6 3/4" (increment of 1/4")
Age: 10 to 80 years old
Gender: Male/Female
Weight Accuracy 2.0 kg to 40.0 kg: ± 0.4 kg, 40.0 kg to 150.0 kg: ± 1% / 4.4 lb to 88.2 lb: ± 0.88 lb, 88.2 lb to 330.0 lb: ± 1% / 4.4 lb to 6 st 4.2 lb: ± 0.88 lb, 6 st 4.2 lb to 23 st 8.0 lb: ± 1%
Accuracy (S.E.E.) Body Fat percentage: 3.5%
Power Supply 4 AAA batteries (R03) (You may also use AAA alkaline batteries (LR03).)
Battery Life Approximately one year (When AAA manganese batteries are used with four measurements a day at a room temperature of 23°C.)
Operating Temperature/Humidity +10°C to +40°C, 30 to 85 % RH
Storage Temperature/Humidity/Air Pressure -20°C to +60°C, 10% to 95% RH, 700 hPa - 1060 hPa
Weight Approximately 1.3 kg (including batteries)
External Dimensions Approximately 285 (W) × 28 (H) × 210 (D) mm
Note: Subject to technical modication without prior notice.
This device fullls the provisions of the EC directive 93/42/EEC (Medical Device Directive).
OMRON HEALTHCARE EUROPE B.V. guarantees this product for 3 years after date of purchase.
The guarantee does not cover battery, packaging and/or damages of any kind due to misusage (such as dropping or physical misuse) caused by the user. Claimed products will only be replaced when returned together with
the original invoice / cash ticket.
11
Troubleshooting
Error DisplayPossible causeCorrection
You step off the unit during the measurement.Do not step off the unit till the measurement is completed.
Your feet are not correctly positioned on the electrodes.Make sure that you are standing on the unit correctly and try again.
The measurement position is not stable or your feet are not
placed correctly.
Remain still and do not move during measurement.
Feet are too dry.Slightly moisten the soles of your feet with a damp towel and try again.
The unit is not set up correctly.Remove the batteries. Wait one minute. Reinstall the batteries. Touch the ON-OFF-SET button and turn on the
power. Retake the measurement.
You step onto the unit before 0.0 kg (0.0 lb) is displayed.Wait until 0.0 kg (0.0 lb) is displayed before stepping onto the unit.
The unit moved before 0.0 kg (0.0 lb) is displayed.Do not move the unit until 0.0 kg (0.0 lb) is displayed
Movement during measurement.Do not move till measurement is completed.
Your weight is over 150.0 kg (330.0 lb or 23 st 8.0 lb).This unit can only be used by people weighing less than 150.0 kg (330.0 lb or 23 st 8.0 lb).
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Omron BF212 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Omron BF212 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.
The manual is 3,88 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.