812263
77
Zoom out
Zoom in
Previous page
1/160
Next page
Operating manual
for the user
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
EN
Note! Motor combustion air damper accessory
(Part number 43/1481.9240)
The combustion air damper is used for automatic opening and
closing of the combustion air line. A closed combustion air line
prevents warm air from escaping from the installation room
unnecessarily.
Observe the instructions enclosed with the combustion air
damper!
Operation while absent
The pellet replace can also be operated while absent in automatic
mode and with a saved frost protection temperature or with operat-
ing via the app. In this case, care must be taken to ensure that pets
or dependants do not remain in the direct radiation range at any
time and no ammable objects are placed on the pellet replace.
People who do not operate the pellet replace but have access to it
must also be informed of this fact!
3.5 Recommissioning
After long periods without operation, check that the chimney
duct is clear!
Check the pellet reservoir and the screw before recommissioning,
after the summer break and before the heating period!
Conduct a visual inspection of the burner trough before every
start and clean the burner trough if necessary. No pellets may be
manually placed in the burner trough (exceptions: during recom-
missioning and if the reservoir runs empty, a handful of pellets
must be poured into the burner trough)!
Note! Power failure or extended period with the master
switch turned o
In the event of a power cut or if the master switch is turned
o for an extended period, the regulation system saves key
combustion-related data and settings. When the power to the
pellet replace is restored, it is regulated to the operating state
before the power failure.
If the pellet replace is without power for more than 14 days,
then the data and time must be reset. The regulation system
recognises this and automatically switches to the “Date/time”
menu after switch-on.
3.6 Behaviour in the event of a chimney re
Caution! Serious personal injury and property damage!
In the event of a chimney fire, proceed as follows in order to
prevent serious personal injury and property damage:
Switch the pellet replace o!
Inform the re department and chimney sweep!
Allow the chimney to burn out in a controlled manner!
Have an expert investigate the cause!
3.7 Operation with the touch control panel
After switching the master switch on, the touch control panel
display is automatically activated and the “HOME display appears.
If no buttons are pressed for 5 minutes, then the display switches
o (energy-saving mode). The HOME display appears again if the
display is touched.
Touch control panel overview and functions
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA 2.0 Aqua
INARA 2.0 6 kW ARINA 2.0 6 kW
example LEVANA
Manual mode
Ready
Party
Actual °C
16:20
17
4
54 6 27 82 31
Fig. 3.11 Functions and information (using the “HOME” display as an
example)
1ON / OFF 5Output stages
2Plus / minus 6Actual temperature
3Time display 7Party function
4Current operating state 8Open a menu
We reserve the right to make technical changes
77
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 7778-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 77 11.04.2023 14:41:5711.04.2023 14:41:57
77


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg LEVANA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg LEVANA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info