3.3 Switching the pellet replace on
Set the master switch to “I” (back right of the appliance)!
After switching the master switch on, the touch control panel
display is automatically activated and the “HOME display appears.
If no buttons are pressed for 5 minutes, then the display switches
o (energy-saving mode). The HOME display appears again if the
display is touched.
Abb. 3.9 Einschalten mit dem Hauptschalter
Hinweis: Der möglicherweise auftretende Geruch durch das
Aushärten der Schutzlackierung verschwindet, wenn der
Pellet-Kaminofen bei guter Raumbelüftung mehrere Stunden
bei Volllast gebrannt hat.
3.4 Application and use of the pellet replace
Warning! Serious personal injury and property damage!
(Burns/fire risk)
The surfaces of the pellet fireplace, particularly the glass
panes of the combustion chamber, get very hot.
You should therefore maintain a sucient distance from
these surfaces and do not hang or lean any objects on the
pellet replace (e.g. to dry or warm)!
Only operate the pellet replace with the combustion
chamber door closed!
Do not use the pellet replace while absent for longer
periods!
Watch small children and do not leave small children unsu-
pervised near the pellet replace while it is in use and hot!
Do not remove hot ashes, and only store ashes in reproof,
non-ammable containers!
Warning! Serious personal injury, environmental damage
and property damage!
Do not under any circumstances use the pellet replace if
you notice malfunctions during operation, in regulation
and control, leaks in the chimney ue, or damage to the
door seals!
In this case, switch the pellet replace o immediately!
Contact a specialist company!
Note! Operating conditions! Two independent drives ensure
the operation of the pellet replace. The induced draft fan
supplies the combustion chamber with sucient combustion
air and the pellet screw conveys the pellets into the combus-
tion chamber. Depending on the operating status, chimney
conditions and pellet quality, these two drives have to work
harder or less hard in order to achieve the desired result. This
can result in diering noise emissions which may temporarily
be louder than usual. This is not a malfunction, but is rather a
result of variable environmental conditions.
Note! Surface changes to the ceramic and natural stone
cladding!
The natural stone cladding is produced from a
“natural” stone block. The texture and colour can therefore
be very dierent. Surfaces can change when subjected to
temperature. Hairline cracks or so-called craquelure can also
occur on ceramic elements.
Opening and closing the inspection door
The inspection door underneath the combustion chamber is
equipped with a magnetic pressure lock. It can be opened by press-
ing lightly on the button (Olsberg logo). Closing is also done by
pressing lightly.
Fig. 3.10 Inspection door with a magnetic pressure lock
76
We reserve the right to make technical changes
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 7678-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 76 11.04.2023 14:41:5711.04.2023 14:41:57
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg LEVANA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg LEVANA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info