744289
8
Zoom out
Zoom in
Previous page
1/16
Next page
8
Activating the combustion air damper
Display Action Description
menu select
settings
information
operation mode
or
The combustion air damper must be activated in the
service level.
Go to the service level via the menu selection, “in-
formation”.
information
service
op.hours
Ver.
ext.req.
GSM mod.
error messages
operating data
service level
on
n.c.
1.00.35 L6
2000h
0h
or
Service level
next
code
enter
0000
or
The password for the service level is: 2012
service level
input data
parameter
relay
components
service
or
Go to the “components” menu using ↓ or ↑ and
(ENTER).
components
grate
supply air
convection no
no
no
or
Select “no” with (ENTER) (“no” ashes) and with
↓ or ↑ change over to “yes”.
Conrm “yes” with (ENTER).
The combustion air damper is now activated.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg Inara at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg Inara in the language / languages: English, German, French as an attachment in your email.

The manual is 1,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Olsberg Inara

Olsberg Inara Additional guide - English, German, French - 8 pages

Olsberg Inara Installation Guide - All languages - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info