812264
87
Zoom out
Zoom in
Previous page
1/160
Next page
Operating manual
for the user
LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
EN
3.9 Error messages and warnings on the display
Error messages
The ongoing combustion process is halted while there is a fault.
If an error message occurs while in standby, then the combustion
process is not permitted to start. An error message is indicated by
the display ashing.
The display notication can only be left with (ESC) once the cause
of the fault has been remedied. Call a service technician where
applicable.
Display notication Possible cause of the fault Possible remedy
Not ignited ū Pellet reservoir may be empty.
ū Burner trough soiled.
Fill the pellet reservoir. Clean the burner trough.
Door open ū Combustion chamber door was open for too long.
ū Chimney blocked.
ū Glass pane damaged.
ū Ash pan not correctly inserted.
ū Airways blocked in the pellet replace.
Close the combustion chamber door!
Check the chimney. Inspect the glass panes!
Push the ash pan in and lock it!
Induced draft faulty ū Induced draft fan not connected.
ū Speed monitoring faulty/not connected.
Call a service technician.
Flame sensor faulty ū Flame temperature sensor faulty.
ū Flame temperature sensor not connected.
Call a service technician!
Room sensor faulty ū Room temperature sensor faulty
ū Room temperature sensor not connected.
Call a service technician!
Safety chain interrupted ū One of the safety devices (safety temperature limit-
ers) has triggered.
Call a service technician!
Flame temperature too low ū Flame temperature has dropped unexpectedly. Fill the pellet reservoir!
Operating temp. too high ū Flame temperature too high for a long period of
time.
ū Screw motor control unit may be faulty.
Call a service technician!
Vacuum sensor faulty ū Vacuum sensor faulty.
ū Vacuum sensor not connected.
Call a service technician!
Air ap faulty
(if installed)
ū Combustion air ap has not opened in the speci-
ed time
Check the combustion air ap!
(Wiring)!
Check the burner trough ū Burner trough blocked / overlled.
ū Burner trough not / incorrectly inserted.
ū Service may be due (if the notication appears
frequently)
Clean the burner trough!
Insert the burner trough!
Check the airways ū Minimum vacuum could not be achieved despite in-
creasing the speed of the induced draft fan.
ū Service may be due (if the notication appears
frequently).
Check the combustion air line!
COM fault ū Communication between the control panel and the
controller board interrupted.
Call a service technician!
Buer sensor 1 faulty ū Buer sensor 1 (top) faulty.
ū Buer sensor 1 (top) not connected.
Call a service technician!
Buer sensor 2 faulty ū Buer sensor 2 (bottom) faulty
ū Buer sensor 2 (bottom) not connected.
Call a service technician!
We reserve the right to make technical changes
87
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 8778-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 87 11.04.2023 14:42:0011.04.2023 14:42:00
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg ARINA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg ARINA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info