Installation of a combustion air damper for automatic opening
and closing of the combustion air line (optional)
A closed combustion air line prevents warm air from escaping from
the installation room unnecessarily with the stove turned o.
Note! The combustion air damper is closed in the “O operat-
ing state. It is open in all other operating states (“Ready”, “Ignition,
“Start, etc.).
The actuator takes approx. 2 minutes to reach the closed” posi-
tion, i.e. the pellet replace may be switched o at the master
switch 2 minutes after “O appears on the display at the earliest.
The user of the pellet replace should also be informed of this
.
1
2
6
7
5 4 3 2
Fig. 2.20 Connection of a motor-driven combustion air damper
1Motor slewing ring
2Stops for the combustion air damper (open/closed)
3“S19” connector
4“L continuous” connector (must be connected to the
“L continuous” mating connector in the wiring harness)
5“S5” connector
6Combustion air damper screwed onto the rear
7Combustion air damper screwed onto the bottom
If other accessories are installed in addition to the automatic, mo-
tor-driven combustion air damper, take care to ensure, for reasons
of accessibility, that the combustion air damper is installed rst.
For the same reason, the side walls should also be installed rst
after installing the combustion air damper!
Connect the combustion air damper connector into the wiring
harness and to the main circuit board of the pellet replace as fol-
lows before installing the combustion air damper:
a) Plug the “19” connector into position “S19” on the main circuit
board (see connection diagram!)
b) Plug the “S5” connector into position “S5” on the main circuit
board.
c) Plug the “L continuous” connector into the “L continuous” con-
nector in the pellet replace wiring harness!
Follow a similar procedure to that which is set out in the “Conversion
of combustion air nozzles for connection from the bottom chapter:
Remove the lower back wall and panel!
Release the hose clamp on the combustion air line!
Remove the combustion air nozzles!
Plug the connecting piece for the combustion air damper into the
combustion air line and tighten the hose clamp again!
Screw the combustion air damper onto the rear or bottom of the
pellet replace!
311x
Fig. 2.21 Remove the lower back wall and panel
64
We reserve the right to make technical changes
78-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 6478-4643-2481_R6_LEVANA 2.0_ARINA 2.0_INARA 2.0_DE-EN-FR.indd 64 11.04.2023 14:41:4711.04.2023 14:41:47
64


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olsberg ARINA 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olsberg ARINA 2.0 in the language / languages: English, German, French as an attachment in your email.

The manual is 34.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info