688917
40
Zoom out
Zoom in
Previous page
1/124
Next page
40
ENGLISH
2
Fasten the drilling template to the wall leaving the necessary space from the ceiling, oor and side walls as shown on the template
that may be xed using adhesive tape.
Use a small drill or punch to mark, with extreme care, the exact centre of each of the holes to be drilled.
Using a core boring head measuring at least 162 mm to drill the two holes for entry and exit of the air.
WARNING: drill the foregoing holes tilted slightly downwards to prevent water from being fed back through the ducts
(g. 7).
Most of the removed material is expelled outwards, therefore make sure that it does not hit any person or object when it falls out.
In order to avoid as much as possible outer plaster breaking, it is necessary to proceed carefully with the last part of hole execution,
decreasing pressure on core borers.
Next, drill the holes for anchoring the fastening brackets to the wall using as a rst option the 4 holes on the ends of the bracket
as shown on the drilling template.
If the wall is not very solid, it is advisable to use some extra anchor bolts.
As you can see, the bracket can be fastened in a number of different ways and positions. The majority of the weight of the appliance
is to the right side so ensure that xing is more secure on this side.The anchor bolts provided require holes with a diameter of 10
mm.
In any case, the wall should be inspected carefully to determine the best possible anchorage and type of bolts suitable for particular
situations.
WARNING: the manufacturer will not be held liable for any underestimates made in the structural consistency of the anchor prepared
by the installer.
Therefore, pay utmost attention to the foregoing operation that could cause serious injury/damage to people/property if carried out
incorrectly.
When installing models equipped with heating pump, if no condensate discharge was built into the wall (see paragraph 2.1.6), in
order to drain the condensate it will be necessary to drill a hole through the wall in the position shown on the template.
2.1.6 Preparing the condensate discharge (gg. 8, 9, 10)
The condensate discharge pipe (supplied) must be connected to the UNICO BOILER MASTER by coupling it with the specic
vent (g. 8 ref. A) that is on the back of the machine (remove cap B). When the max level is reached, a solenoid valve ensures the
condensate will ow out from the internal tray.
Since condensate drains by gravity, there must be a minimum slope of at least 3% at every point of the discharge line. Use a rigid
or exible tube having an inside diameter of at least 16 mm.
If the line empties into a sewerage system, install a siphon before the point in which the pipe reaches the main discharge, at least
300 mm below the inlet from the unit (g. 8).
If the drainpipe drains into a vessel (tank or other container), this container should not be sealed and the drainpipe should not
remain immersed in the water (see g. 9).
The hole through which the condensate pipe passes should always slope towards the outside (see g. 10).
The exact position in which to place the pipe inlet, as compared to the machine, is shown on the drilling template.
CAUTION: make sure, in this case, that the water expelled outward does not damage or disturb persons or property.
During the winter this type of drainage may cause sheets of ice to form.
When the condensate drainage is tted, pay much attention not to compress the rubber hose.
2.1.7 Assembly of the air ducts and external grids (g. 11, 12, 13, 14, 15, 16)
After having drilled the holes, insert the plastic sheet supplied with the conditioner into them.
Since the sheet was made for 202 mm holes, you will have to cut off 130 mm from the long side of the sheet for the 162 mm holes.
The length of the sheets must be 65 mm less than the thickness of the wall.
Roll the sheet and insert it into the hole (g. 11), paying attention to the splicing line (g. 11 ref. A), which must always
upwards.
Use an ordinary cutter for the foregoing operation (g. 11).
To position the external grids, proceed as follows:
- Apply the seal (g. 12 ref. B) to the wall ange (g. 12 ref. A), ensuring it lines up with the outer edge of the ange as indicated
in the gure.
- Fix the two anges using 2 pegs having a diameter of 6 and check that the two xing holes are horizontal.
- Fit the small eyelet of the spring, with the long stem, on the cap pin (on both components) (g. 13).
- Insert the two caps (with spring), on the front part of the external grid, on its two housings, pulling until it clicks (g. 14) and
couple the two chains to the large eyelet of the spring.
- Using one hand, grip the two chains connected to the grid.
- Bend the external grids back, gripping them with your free hand where they bend, and insert your ngers inside the single
2
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Olimpia Splendid Unico Boiler at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Olimpia Splendid Unico Boiler in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 21,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info