18
GB
Instructions
Dear Client,
We thank you for having chosen one of our products, the fruit of technological experience
and of continual research for a superior quality product in terms of safety , dependability ,
and service.
In this manual you will find all the information and useful suggestions to use your product
with the maximum safety and efficiency .
t Incorrect installation, incorrectly performed maintenance, improper use of the product
release the manufacturer from every eventual damage derived from the use of the
stove.
t The unit cannot be used as an incinera tor . Do not use fuels other than pellets.
t This manual has been realized by the manufacturer and constitutes an integral part
of the product and must remain with it during its entire lifetime. If the product is sold
or transferred, be sure tha t the booklet is present since the information contained in
it are addressed to the buyer , and to all those persons of various titles who complete
the installation, use and maintenance.
t Carefully read the instructions and the technical information contained in this manual,
before proceeding with the installation, use, and any operation on the product.
t The obser vance of the indications contained in th e present manual guarantees the
safety of people and the product, the economy of use and a longer functioning life-
time.
t Although the carefully studied design and the risk analysis done by our compan y has
permitted the realization of a safe product, in any case, before effecting any operation
on the stove, it is recommended to keep said manual a vailable and pay scrupulous
attention to the instructions written therein.
t#FWFry careful when moving the ceramic details where present.
t$IFDLUIFQSFDJTFnatness of the pavement where the product will be installed
t The wall where the product will be placed must not be constructed in wood, or in any
case, made of an JOnBNNBCMF ma terial, and in addition it is necessar y to maintain a
safety distance.
t While the stove is in opera tion, several parts of the stove (door , handle, sides) can
reach high temperatures. Therefore pay attention and use the proper precautions,
above all in the presence of children, elderly or disabled persons, and animals.
tAssembly must be performed by authorized persons (Authorized Assistance Centre).
t Diagrams and drawings are furnished for the purpose of illu
stration; the manufacturer ,
with the intent of pursuing a policy of constant development and renewal of the product
can, without an y notice, make any modifica tions that are believed opportune.
t When the stove is working at its maximum speed, it is strongly suggested to wear
gloves while handling with the door for pellets loading and the door handle.
t*OTUBMMation is not recommended in a bedroom.
In the event of a fire, disconnect the power supply, use an extinguisher and call
the fire fighters if necessary . After that contact the Authorised Assistance Centre.
1.0 Norms and declarations of conformity
1.1 Safety Information
Please carefully read this use and maintenance manual before installing and operating
the stove!
If clarification is needed, please contact the dealer or the Authorized Assistance Centre.
t The pellet stove must only be opera ted in living environments. This stove, being con-
trolled by an electronic board, permits a completely automa tic and controlled combu-
stion; the exchange, in fact, regulates the lighting phase, 5 po wer levels and the shut
down stage, guaranteeing the safe operation of the stove.
t The basket used for combustion allo ws most of the ash produced by the combustion
of the pellets to fall into the collection compartment. Nevertheless, check the basket
daily , given that not all pellets have high quality standards (use only quality pellets re-
Please remember that the first lighting of the stove must be handled
by our Authorized Assistance Centre (Law 37/2008) who will check
the installation and complete the guarantee.
Never cover the body of the stove in any way or obstruct the ope-
nings placed on the upper side when the device is operating. All our
stoves are trial lighted on the construction line.
t The stove must only be fed with quality 6mm diameter pellets of
the type recommended by the manufacturer;
t Before making the electrical connection of the stove the discharge
tubes must be connected with the flue;
t The protective grill placed inside the pellet container must never
be removed;
t The environment where the stove is installed must have a suffi-
cient exchange of air;
t/FWFSPQFOUIFEPPSPf the stove while it is operating;
t When the stove is operating, the surf aces, glass, handle and tubes
become very hot: during operation do not touch these parts wi-
thout adequate protection;
t,FFQTUPSFUIFQFMMFUTJOBDPPMEry place;
t,FFQUIFGVFMBOEPUIFSJOflammable materials off the stove.
commended by the manufacturer).
t The glass is equipped with a special circula tion of air for self-cleaning, but still, it is
not possible, after several hours of opera tion, to keep a light grey patina from forming
on the glass. This also depends on the type of pellets used. Some pellets deposit more
ash than others.
1.2 Responsibility
With the delivery of the present manual, we dec line all responsibility , both civil and penal,
for accidents deriving from the partial or total lack of observance of the instructions
contained herein.
We dec line ever y responsibility derived from improper use of the stove, from incorrect
use by the user , from unauthorized modifications and/or repairs, from the use of re-
placement parts that are not original for this model.
The manufacturer declines every civil or penal, direct or indirect responsibility due to:
t-BDLPGNBJOUFOBODF
tFailure to observe the instructions contained in the manual;
t6TFJOOPODPOGPSNJUZXJUIUIFTBGFUZEJSFDUJWFT
t*OTUBMMBtion in non-conformity with the norms in force in the country;
t*OTUBMMation by unqualified or untrained personnel;
t.PEJmDations and repairs not authorized by the manufacturer;
t6TFPGOPOPSJHJOBMSFQMBDFNFOUQBSUT
t&YDFQUJPOBMFWFOUT
2.0 Stove panel and remote control
1) T emperature working power decrease: sing the key on the menu Set tempera-
ture, you can decrease the temperature from a max. value of
°C to a min. value of
7°C. With the key on the menu Set power , you can decrease the working power from
a max. value of 5 to a min. value of 1.
T emperature working power increase: the key on the menu Set tempe-
rature, you can increase the temperature from a min. value of 7°C to a max. value
. With the key on the menu Set power , you can increase the working power
from a min. value of 1 to a max. value of 5.
3)
: switch the stove on or off.
4)
: This led indicates the different phases of the stove:
- it is on if the stove is switched on and working
- it is off if the stove is switched off
- it blinks if the stove is switching off
5)
: The led blinks in the event of a malfunction or alarm.
6) LED chrono-thermostat: This means the automatic single or daily programming of
the switching on or off of the stove is on. The automatic programming can be set
with the remote control (optional) or with the control board.
7) LED temperature ok: This is on when the stove reaches the set temperature. In this
case you will read the word i&DP ” and the set temperature on the display .
8) LED pellets loading : This led blinks every time the stove is loading pellets.
9) LED resistance : This led is on only while the stove is lighting up in order to indicate
10 ) Display LED 7 segments: On the display you can read the different working fun-
ctions of the stove, the room temperature and the set working power . In the event
of a malfunction, the display shows the relative error codes (see paragraph on alarm
codes).
-
+
AL
5 6 8 10 4
1 2 7 9 3
t3FHVMa UJPOPGUIF$13&6
chnician installing the hydrothermal sanitary system will issue the declaration of con-
formity according to - . 37/2008. The installation of a ppliance has to be in accordance
with local and national laXTBOEXJUI&VSPQFBOOPSNT
t&/&/&/&/&/
&/&/&/&/
t Our company declares that the stove conforms to the following norms for &$ &uropean
Directive marking.
t&6&MFDUSPNBHOFUJD$PNQBUJCJMJUZ%JSFDUJWF&.$%
t&6-PX7PMUBHF%JSFDUJWF-7%
t&63FTUSJDUJPOPGUIFVTFPGDFSUBJO)B[BSEPVT4VCTUBODFTJOFMFDUSJDBMBOE
FMFDUSPOJDFRVJQNFOU3P)4%JSFDUJWF
Failure to carry out maintenance or maintenance not carried
out as stated in this manual may cause danger and harm to
persons or property.
t