While operating in NORM or GAUG Mode the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that
time, the Audible can be acknowledged and silenced by pressing the S button (less than 2 seconds).
A LED Warning Light, on the lower end of the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn Off when the Alarm
is silenced. The Audible and LED will not be active if the Audible is Set OFF (a group A setting).
FREE Dive Mode has its own set of Alarms which emit 3 short beeps either 1 or 3 times which cannot be acknowledged or set Off.
Situations that will activate the NORM/GAUG 10 second Alarm include -
** Items activate only in NORM mode.
• Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
• Turn Pressure at the Set Point selected (Transmitter 1 only).
• End Pressure at the Set Point selected (active Transmitter).
• Descent deeper than the Depth Alarm Set Point selected.
• Dive Time Remaining at the Set Point selected**.
• Elapsed Dive Time at the Set Point selected.
• PO2 at the Set Point selected**.
• High O2 of 300 OTU (100%)**.
• TLBG at the Set Point selected**.
• Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
• Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
• Entry into Decompression Mode (Deco)**.
• Conditional Violation (above a required Deco Stop Depth for less than 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth for more than 5 minutes)**.
• Delayed Violation (a Deco Stop Depth greater than 60 FT/18 M is required)**.
• Delayed Violation (Max Operating Depth of 330 FT/100 M is exceeded).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA**.
• Watch Daily Alarm reaches time set (disabled during Dive Modes).
• Watch Mode Countdown Timer reaches 0:00.
A single short beep (which cannot be disabled) sounds when -
• After 5 minutes on the surface after the Violation dive.
3 short beeps (which cannot be disabled) sound when -
• Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and shallower.
• FREE Dive Elapsed Dive Time Alarm (3 beeps every 30 seconds if set On).
During the following NORM Dive situations, the 10 second continuous tone will be followed by a 5 second steady beep that will not turn off when acknowl-
edged -
• Ascent above a Deco Stop for more than 5 minutes.
• Deco requires a Stop Depth of 70 FT/21 M or deeper.
• On the Surface for 5 minutes after a Conditional Violation.
PC INTERFACE
Interface with a PC, to allow uploading settings and downloading data, is accomplished by connecting the OC1 to a PC USB Port using the special OC1
USB Interface Cable.
The software program together with the USB Driver required is on the Oceanlog CD, and can be downloaded from the OceanicWorldwide web site. The
program's HELP** serves as the user manual which can be printed for personal use.
** Prior to attempting to Download data from your OC1 or Upload Settings to it, review the HELP section of the Oceanlog program. Recommended is to
print those sections of HELP that you consider appropriate for your Interface activities.
The Settings Upload portion of the Oceanlog program can be used to set/change the Main Time, Date, Set A group (Alarms), and Set U group (Utilities)
using the same Interface System. FO2 and FREE Mode related items must be set using the control buttons.
Information available for retrieval (download) from the OC1 to the PC Download portion of the program includes dive data such as number, surface inter-
val time, maximum depth, elapsed dive time, no deco status, pressure, start date/time, lowest temperature under water, sampling rate, dive profile, and Set
Points.
The Oceanlog program also allows upgrade of select versions of the OC1's firmware (operating system software) after which the OC1 resets all operating
data. Since the upgrades require reset of the OC1, they are blocked during 24 hours after dives.
• Refer to page 58 for more details relating to Oceanlog and PC Interface.
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Oceanic OC1 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Oceanic OC1 in the language / languages: English as an attachment in your email.
The manual is 8,03 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.