REMEDY OF FAULTS
WARNING
Dangerous electrical voltage!
Death or severe injury from electrocution.
Prior to starting work:
Switch off the unit, disconnect the power plug and secure the unit from being switched
on again.
Before stepping into or reaching into the water, switch off all units located in the water.
On completion of the work:
Restore all the prerequisites for start-up.
Malfunction
Cause
Remedy
Pump does not start.
Power supply interrupted
Check the fuse and electri-
cal plug connections.
Pump switches off after a
short running period.
Overload protection has
switched the pump off due
to overheating.
Clean the intake
Allow the pump to cool
down.
The well has run dry.
Wait until there is sufficient
water in the well.
The pump is running but is
not delivering, or the deliv-
ered quantity is insufficient
Pressure hose blocked
Route the pressure hose
without kinks
Check the outlet and
clean if necessary
Intake blocked
Clean the intake
Air in the pressure hose
Expel the air from the
pressure hose.
If applicable:
Non-return valve incorrectly
fitted in the pressure hose
or clogged
Correctly fit the non-re-
turn valve
Clean the non-return
valve.
Impeller defective or worn
Contact OASE
The impeller may only
be replaced by the
OASE Service.
The impeller is clogged
with sand.
Contact OASE
The impeller may only
be replaced by the
OASE Service.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Oase ProMax Pressure Well 6000-8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Oase ProMax Pressure Well 6000-8 in the language / languages: All languages as an attachment in your email.

The manual is 3,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info