Installation instructions for sectional doors type
iso 9/20 with extension spring, disassembled
version
The door manufacturer accepts no liability for incorrect
mounting.
– Mounting should only be carried out by qualified fitters
Please read carefully before mounting
Scope of delivery:
Section package, frame package, panel package
The following items are required for mounting
the following tools (place inside the garage before mounting
the door if there is no other entrance to the garage)
folding rule/tape measure, water level, water pump pliers, re-
versible ratchet handle with extension and wrench socket
inserts size 7, 10 and 13 ( fork or wrench socket also possible)
fork or open spanner from size 13 for tightening springs (cf.
Item 29), cross-tip screwdrivers size 2 and 3, slot screwdriver,
hammer drill with drill bits, Ø 10 mm (drilling depth of at least
65 mm), at least 2 screw clamps, possibly square timber,
hammer, chisel and
Mounting material suitable for the building situation. Note:
Check that the wood screws
S2 supplied and the plugs
D1 are suitable for the building situation before use.
Important :
The door may only be mounted in a finished opening and
on a finished floor!
As a precautionary measure, compare the garage dimensions
with the coordinating size of the door before mounting.
minimum inside width of garage
= coordinating size –width + 200 mm
minimum garage ceiling height
= coordinating size –height + 120 mm (also suffices for
door operators)
minimum side room right and left = 55 mm
All references in these instructions to left/right always
refer to the view from inside the garage looking out! All
dimensions are in millimetres. The information given is
subject to change without notice. Letters and figures on a
grey background, for example
S1, refer to the correspon-
ding mounting material in the illustrated section. Figures
on a grey background, for example
2, refer to the corre-
sponding parts in the exploded views (subsequently a
subscripted L or R, for example
1
L
: Parts for the left or
right side are different (Observe the markings on the
parts), without subscription = usable right/left).
Mounting of door frame
1 Lay the angular frames
1
R
+
1
L
on to wood or something
similar (to protect them from scratches) and screw together
the angular frame
1
L
+ frame panel
2 + angular frame
1
L
+
track connector
3 (tapping screws have already been pre-
mounted).
2 Loosely screw the wall anchor
4 to the angular frames
1
R/L
right and left with
S1 +
M1 according to the side
room.
2a Side room 55–120 mm: Set the wall anchor
4 to the
inside.
2b Side room more than 120 mm: set the wall anchor
4
to the side.
If other mounting materials are used, make sure they
have at least the same load-carrying capacity as the
supplied wall anchor
4.
3 Set up the door frame behind the opening, secure it so it
cannot fall over, and use the water level to align exactly
parallel and at a right-angle (check the rectangularity by
comparing the two diagonal distances; also ensure that the
frame panel
2 is level). Centre and clip panel retainers
7 to
the upper frame part. Finally fasten with
S2 +
D1 as well as
S1 +
M1 Note: do not twist or bend the angular frames
1
R/L
; it might be necessary to fill the space between
frame and masonry with suitable material before tight-
ening the screws!!!
4 Remove the track connector
3 completely, including tap-
ping screws.
5 Screw each of the right
5
R
and left
5
L
pair of horizontal
tracks to end connection bracket
6
R/L
+ spring channel
bracket
8 each front & back + end piece
11
R/L
+ spring
channel
12 + cable deflection pulley
13 . Mount (
S1 +
M1)
and foamed rubber
9
5a
5f
6 Screw the horizontal pair of tracks
5
R/L
to the end pieces
11
R/L
with the header bracket so that later the door re-
mains raised when lifted up. To do so:
in the case of side rooms of 55–120 mm: screw
S3
loosely to
M1. Insert
S3 through the rectangular hole in
the end piece
11
R/L
and header bracket, turn by 90°,
so that the square catches in the hole in the frame
11
R/L
. Tighten
M1 by hand.
In the case of side rooms of more than 120 mm: Insert
S4 through the rectangular hole in the end piece
11
R/L
and header bracket and screw by hand to
M1
7 Mounting of anchor tracks
14
7a If the distance between the wall and the pair of hori-
zontal tracks
5
R/L
is smaller than 500 mm (internal
width of the garage max. coordinating size +1030 mm
if door is fitted in the middle) push an anchor track
14
right and left into the track connector
3 and screw the
clamping plate
15 to
S1 +
M1 in such a way that the
anchor tracks can still be pulled out.
7b If the distance between the wall and the pair of
horizontal tracks is more than 500 mm the track
connector
3 can be later fixed to the ceiling (Cf.
Point. 15).
8 Screw the track connector
3 each with
S1 +
M1 to the end
connection brackets
6
R/L
.
9 Hook a mounting aid
16 into the upper rectangular holes of
the angular frames
1
R/L
.
10 Premount springs. Place both triple extension spring as-
semblies
17 with the plastic sliding elements downwards
on the floor of the garage (with the spring tightening strap
pointing to the back wall of the garage). Screw a deflection
pulley cable assembly
18 with the black side showing up-
GB
The instructions for installation, operating and maintenance must be kept in a safe place as long as the door is in use! -6-
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Novoferm iso 9-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Novoferm iso 9-1 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 5,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info