FIXATION AT CORNERS AND TEE CONNECTORS
Standard distance between pipe brackets is some 2 m.
MOUNTING OF PIPE LINES/GENERAL INSTRUCTIONS
- Shorten the pipes by sawing off and take off burrs.
- When bending the pipe bending radii should not be smaller than those stated in the chart
under “U-bends/hose connections” and the bending should always be completed in a bend-
ing tool with rolling matrixes in order to prevent deformation of the pipe.
- Union nut and cutting ring should be greased with oil and the cutting ring should be pre-fitted
to the pipe in the screw joint or the annealed pre-mounting socket before fitting the pipe.
- Place the pipe brackets at a maximum interval of 2 m.
- Use 6 hexagon-headed screw with expansion joint for wall or concrete walls when
mounting wall fittings, alternatively use a knock-type anchor for concrete walls, e.g. HILTI
type HPS 8/30.
- In systems meant for hot water, care should be taken to place the pipe brackets on a straight
line in order to prevent the lengthwise expansion of the pipe.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nilfisk-ALTO DELTABOOSTER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nilfisk-ALTO DELTABOOSTER in the language / languages: English as an attachment in your email.

The manual is 1,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nilfisk-ALTO DELTABOOSTER

Nilfisk-ALTO DELTABOOSTER Additional guide - English - 1 pages

Nilfisk-ALTO DELTABOOSTER Additional guide - German - 1 pages

Nilfisk-ALTO DELTABOOSTER User Manual - German - 56 pages

Nilfisk-ALTO DELTABOOSTER User Manual - Dutch - 62 pages

Nilfisk-ALTO DELTABOOSTER Additional guide - French - 1 pages

Nilfisk-ALTO DELTABOOSTER User Manual - French - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info