641176
111
Zoom out
Zoom in
Previous page
1/120
Next page
111
The configuration parameters are:
Device Name: This field controls the top-level name of the device in the Dashboard tree.
It defaults to “Standalone Encoder”. Changes to this field take effect immediately.
IP Configuration: This field selects the control port IP configuration mode, as follows:
o Static IP: This option selects a static IP configuration, specified by the IP
Address, Subnet Mask, Default Gateway and DNS Server fields.
o DHCP: This option selects control port IP address configuration by DHCP. If
this option is selected, the IP Address, Subnet Mask, Default Gateway and DNS
Server fields are not shown.
IP Address: This field is only shown if IP Configuration is set to Static IP. Enter the
desired control port IP address. You cannot set this IP address to the same value as the
Ethernet1/Ethernet2 IP addresses (see the Network Tab section earlier in this document).
Subnet Mask: This field is only shown if IP Configuration is set to Static IP. Enter the
desired control port subnet mask.
Default Gateway: This field is only shown if IP Configuration is set to Static IP.
Enter the desired control port default gateway.
DNS Server: This field is only shown if IP Configuration is set to Static IP. Enter the
desired DNS Server IP address. Note that DNS is only used for RTMP output. This field
can be left at 0.0.0.0 if RTMP is not used. If you wish to configure more than one DNS
server, you can enter them in the Network Configuration DNS Tab. If you configure
DNS servers here and in the Network Configuration, the server specified here will be
contacted first.
NTP Server: If you want the unit to be NTP-synchronized (for logging purposes), enter
the IP address of an accessible NTP server in this field. If you do not need NTP, you can
leave this field at 0.0.0.0. If your B264 has access to the Internet through the control port,
you can point it to one of the public NTP servers for your region. You can find more
details on this link:
http://psp2.ntp.org/bin/view/Servers/WebHome
Apply/Cancel: Use these buttons to apply or cancel the changes to the control port IP
configuration. Note that if you change the IP address, DashBoard may lose contact with
the B264. The IP Address, Subnet Mask and Default Gateway entries will be checked for
consistency and will be rejected if invalid.
Control Port Statistics Tab
The Control Port statistics screen is depicted below. It contains the current settings for the
control port. If you have configured the unit for DHCP, it will include the current IP Address,
Subnet Mask, Default Gateway and the first DNS server obtained from the DHCP server. It also
includes the link state for the individual control Ethernet ports.
111


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Niagara B264 Standalone Encoder at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Niagara B264 Standalone Encoder in the language / languages: English as an attachment in your email.

The manual is 3,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Niagara B264 Standalone Encoder

Niagara B264 Standalone Encoder Quick start guide - English - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info