641176
110
Zoom out
Zoom in
Previous page
1/120
Next page
110
Control Tab
The Control Tab is used to configure the management Ethernet ports in the B264. This includes
both the IP information, as well as the SNMP parameters. The Control Tab is only displayed for
the B264.
The B264 has two physical management (control) Ethernet ports. However, from a logical
standpoint, they are a single port with a single IP address; the two connections are provided for
control redundancy. If one port loses link, the unit can still be controlled from the other. If you
do not need control redundancy, you can leave one of the ports disconnected. The unit will
automatically and dynamically select the control port as follows:
If only one port has link, that port will be used for control.
If both ports have link, but at different speeds, the port with the highest speed will be
used for control.
If both ports have link at the same speed, Port 1 will be used for control.
Both ports support operation at 10, 100 and 1000 Mb/s, both half-duplex and full-duplex, with
auto-negotiation and auto-crossover detection.
The Control Tab has two bottom tabs:
Control Port is used to configure the IP parameters of the control port.
SNMP is used to configure the SNMP parameters for the unit.
Control Port Configuration Tab
The control configuration window is depicted below:
110


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Niagara B264 Standalone Encoder at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Niagara B264 Standalone Encoder in the language / languages: English as an attachment in your email.

The manual is 3,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Niagara B264 Standalone Encoder

Niagara B264 Standalone Encoder Quick start guide - English - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info