LCD KEYPAD 17
[new user code]
Prompts for a user number. Repeat steps 3 and 4
if another user code needs to be programmed.
Keypad will beep 3 times if code is rejected.
# while display is prompting
for a user number.
Exits and saves data.
7m. ASSIGNING AUTHORITY LEVEL
You must have authority to the partition you wish to add or remove from another person’s authority.
ACTION RESULT
Prompts “Please Enter Your Code".
[master code]
Prompts for a user number.
[user code]
2-digit ID if NX-4, NX-4V2, NX-6,
NX-6V2, NX-8, NX-8V2, NX-8-CF
3-digit ID if NX-8E, NX-8E-CF (use
leading zeros!! (i.e.  for user 7)
Prompts through the following list of attributes.
Outputs used?
If NO… If YES…
Master code? Output 4 enable?
Sched arm only? Output 3 enable?
Arm only? Output 2 enable?
Reserved Output 1 enable?
Open / Close Rprt?
Bypass enable?
Arm / Disarm?
[partition number]
Default allows access to ALL partitions.
The first keypress will remove access to the
partition. To reestablish access, press the partition
number again.
Saves data. Prompts for next user code. Return to
step 3 to program another user code.
#
Exits this mode.
NOTE TO INSTALLER: Any master arm/disarm code can add or change a user code if the master
code has access to the same partitions as the code being added/changed. Consequently, when
programming the user codes for a partitioned system, leave at least one code access to all
partitions or you will not be able to add new users (can be "go to program code" if enabled in
location 43 of the control panel). If you desire the end user to be able to add new codes, you must
remove the partition authority from all blank codes.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for NetworX NX-148E LCD Keypad at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of NetworX NX-148E LCD Keypad in the language / languages: English as an attachment in your email.

The manual is 0,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info