646452
108
Zoom out
Zoom in
Previous page
1/154
Next page
99NetBotz Appliance User’s Guide
Restore
Use the Restore icon to restore your appliance configuration using a configuration file created using the
Backup icon.
For more information, see “Backup” on page 74.
To restore your appliance configuration:
1. Double-click the Restore icon.
2. In the Backup file field, enter the name and fully qualified path to the backup file or click
Browse to navigate to the drive and directory in which the backup file is stored. Select the file
then click OK.
3. In the Password field, enter the password used to protect the backup file.
4. Click OK. You will be prompted to reboot the appliance.
5. Click Reboot. The appliance automatically reboots. This may take a few minutes during which
time Advanced View will be unavailable.
Serial Devices
Note: The Serial Devices icon appears only when you have connected a USB modem,
Sealevel I/O device, Modbus USB-to-RS485 adapter, APC Switched Rack PDU, or Wireless
Sensor Pod 180 to the appliance.
For more information about supported USB modems, Sealevel I/O devices, and APC
Switched Rack PDUs, and how they connect to the appliance, see the installation and quick
configuration manual included with your appliance. For more information about the Wireless
Sensor Pod 180, and how it connects to the appliance, see the installation manual included
with the device.
USB modems, Sealevel I/O devices, and APC Switched Rack PDUs all provide serial communication
with the appliance. When these devices are connected to the appliance, the appliance detects the device
and entries for serial ports automatically appear in the Serial Devices window. Through the Serial
Devices window, you specify what kind of device is connected to each serial port. You can also label the
port to which each device is connected.
If a previously detected serial port is no longer detected by the appliance (for example, if an APC
Switched Rack PDU has been disconnected from the appliance), a Remove button appears beside the
port. Click Remove to remove the port configuration.
108


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for NetBotz NBWL0455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of NetBotz NBWL0455 in the language / languages: English as an attachment in your email.

The manual is 1,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info