OPERATORS INSTALLATION GUIDE
The appliance must be installed in compliance with current regulations (Building
Regulations j 1/2/3). It must be placed at least 40 cm (16’’) away from any
combustible materials. lt may be necessary to protect the wall and surrounding
materials. The appliance must be placed on a solid, fire proof hearth conforming to
the current regulations. Ensure that the chimney is free from soot and debris and
is as straight as possible. (Fig 5) the chimney must be impermeable and its sides
not too rough. The connection between the unit and the chimney must be airtight
and made with noncombustible materials, protected against oxidation (enameled
or stainless steel flue pipe).
If the chimney is in poor condition or creates a poor chimney draught, consider lining
the flue. It is very important that the chimney does not create an excess draught. Consider
planning for the inclusion of a draught stabilizer in the installation, Alternatively
(recommended) a chimney cowel, designed to stabiliser flue conditions. The Aerocowel is
one such cowel sold for this purpose.
Stove flue outlet sizes
396 92 Internal : 125 mm 396 96 Internal : 153 mm
Extemal : 139 mm Extemal : 167 mm
The chimney will be sufficiently high and clear of the house ridge by at least 1
meter to prevent any down draught. It will be protected by insulating material in
order to reduce the risk of soot stains in the top part of the flue and possibly be
fitted with a cowl to keep out the rain.
FIG.5
5
Good
Bad
Thermostat setting.
Adjust to 5 mm of
opening.
When the stove is
cold.
5 mm for wood and
coal
O mm for coal only.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nestor Martin HARMONY III MF - 39696 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nestor Martin HARMONY III MF - 39696 in the language / languages: English, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info