English
Malfunctions and the display codes of the boiler
At the beginning of the day, the installation is heated up
too far, too long.The rooms become too warm.
1. Lower the temperature in the clock program, for the
switching point of the beginning of the day.
2. Raise the PID setting, so that the installation will burn less
intensely.
3. If the capacity of the boiler is much higher then necessary, the
water will be heated up too fast. By means of the partial load
potentiometer on the UBA, the maximum capacity for heating
up the water can be reduced, so that the water will be heated
up more slowly.
4. If the rooms have been equipped with too many or too large
radiators, the house can also be heated with water of a lower
temperature.The maximum temperature setting of the water
can be reduced on the UBA.
The room becomes too warm (warmer then the set
temperature).
1. Is the IRT 30 thermostat able to measure the correct
temperature (only for RR and WD + RTC)? Is the IRT 30
thermostat installed on a cold outside wall or in stream of
draught?
2. If the rooms have been equipped with too many or too large
radiators, the house can also be heated with water of a lower
temperature.The maximum temperature setting of the water
can be reduced on the UBA.
3. Are the thermostatic radiator valves installed correctly?
(Is cold air streaming around the thermostatic radiator valves)?
It is too cold (colder then the set temperature) in the
room.
1. Is the IRT 30 thermostat able to measure the correct
temperature (only for RR and WD + RTC)? Is the IRT 30
thermostat installed between cupboards (no natural airflow)
or in the vicinity of heat sources (tv, refrigerator, radiator,
etc.)?
2. Are the thermostatic radiator valves completely open in the
room where the thermostat has been installed?
3. Check the setting of the maximum CH water temperature on
the UBA (90 °C maximum).
4. Has the pump switch on the UBA been set to position 2 (only
for WD and WD + RTC)?
43


Need help? Post your question in this forum.

Forumrules
1

Forum

nefit-moduline-30

Reset search

  • Water temp on my thermor onix connect too high. Boiler currently on eco. Mode. Submitted on 10-1-2023 at 10:33

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit Moduline 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit Moduline 30 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit Moduline 30

Nefit Moduline 30 User Manual - German - 51 pages

Nefit Moduline 30 Usermanual and installation guide - Dutch - 50 pages

Nefit Moduline 30 Quick start guide - Dutch - 2 pages

Nefit Moduline 30 User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info