Setting the temperature control
6. Setting the temperature control
6.1 Selecting a temperature control
The IRT 30 thermostat is suitable for 3 kinds of temperature
control:
- Room temperature controlled regulation (RR)
- Weather dependent regulation (WD)
- Weather dependent regulation with room temperature
compensation (WD + RTC)
Select one of these control before you continue. Chapter 3
describes the points of attention for making your choice.
You have selected room temperature controlled
regulation (RR)
Set the thermostat as follows:
1. Go the CH menu; refer to paragraph 6.2.
2. Set room temperature controlled regulation.
3. Leave the CH menu.
4. Continue with setting the hot water supply; refer to chapter 7.
You have selected weather dependent regulation
(WD or WD + RTC)
Set the thermostat as follows:
1. Go the CH menu; refer to paragraph 6.2.
Only change the settings mentioned below!
2. Set weather dependent regulation.
3. Select the correct installation type.
4. Leave the CH menu.
5. Wait for 3 or 4 hours.
Firing characteristic
The firing characteristic is a line which shows the temperature
of the CH water at a certain outside temperature.You can set
the firing characteristic with the help of 2 points:
- the desired water temperature at +20 °C outside
temperature;
starting point
- the desired water temperature at -10 °C outside
temperature;
end point