4 Commissioning
4.1 Setting the coding card
When the coding card is in a valid position, the indicator lights
up green continuously. When the coding card is in an invalid
position or an intermediate position, the indicator does not
light up initially. It then starts to flash red.
Assigning heating circuits via coding card:
•1 heating circuit:
Coding card on 1
•2 heating circuits:
Heating circuit 1 = coding card on 1;
heating circuit 2 = coding card on 2
•3 heating circuits:
Heating circuit 1 = coding card on 1;
heating circuit 2 = coding card on 2;
heating circuit 3 = coding card on 3 etc.
Assigning cylinder primary circuit (1 or 2) via coding card:
1 cylinder primary circuit: coding card on 9
2 cylinder primary circuits:
Cylinder primary circuit 1 = coding card on 9;
Cylinder primary circuit 2 = coding card on 10
4.2 System and module commissioning
4.2.1 Settings for heating circuit
1. Assign the module to a heating circuit (1-4).
2. Set the coding card on other modules as applicable.
3. Connect the entire system to the mains voltage.
When the module indicator lights up green continuously:
4. Commission and set up the user interface as described in
the accompanying installation instructions.
4.2.2 Settings for cylinder primary circuit
1. Assign the module to a cylinder primary circuit (9 or 10).
2. Set the coding card on other modules as applicable.
3. Connect the entire system to the mains voltage.
When the module indicator lights up green continuously:
4. Commission and set up the user interface as described in
the accompanying installation instructions.
First make all electrical connections and then
carry out the commissioning!
Follow all installation instructions for all
components and assemblies in the system.
Make sure that multiple modules do not
have the same coding.
Only switch on the power supply when all
modules are set up.
NOTICE: Connected pumps can start as soon
as the system is switched on unless the control
unit has detected the module.
Fill the system before switching it on so
that the pumps do not run dry.
When a heating circuit is connected directly to the
heat appliance, the coding card must not be set to
1 on any of the modules. In this case, the first
heating circuit after the low loss header is heating
circuit 2.
When a cylinder primary circuit is connected
directly to the heat source, the coding card must
not be set to 9 on any of the modules. In this case,
the cylinder primary circuit behind the low loss
header is cylinder primary circuit 2.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit MM100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit MM100 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 6,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info