614013
11
Zoom out
Zoom in
Previous page
1/88
Next page
Contents | 11
6 720 816 739 (2015/05)MC 400
Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . 11
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . 11
2 Product details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1 Important information on use . . . . . . . . . . . . . . . . . . . . 12
2.2 Function description / control strategies . . . . . . . . . . . 12
2.2.1 Serial standard cascade . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.2 Serial optimized cascade . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.3 Serial cascade with peak load coverage . . . . . . . . . . . . 12
2.2.4 Parallel cascade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2.5 Output control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.2.6 Flow temperature control . . . . . . . . . . . . . . . . . . . . . . . 13
2.3 Setting the coding card . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.6 Additional accessories . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.7 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2.1 Connecting the BUS connection and temperature
sensor (extra-low voltage side) . . . . . . . . . . . . . . . . . . .14
3.2.2 Connecting the power supply, pump and mixer
(mains voltage side) . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3.2.3 Connection diagrams with system schematics . . . . . . 15
3.2.4 Overview of the terminal assignment . . . . . . . . . . . . . . 16
4 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1 Setting the coding card . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2 System and module commissioning . . . . . . . . . . . . . . . 17
4.2.1 Settings for systems with a cascade module in the
BUS system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.2.2 Settings for systems with two or more cascade
modules in the BUS system . . . . . . . . . . . . . . . . . . . . . .17
4.3 Status display for the heat source/subordinate
cascade modules on the subordinate cascade
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
4.4 Status display for the heat source on the
subordinate cascade module . . . . . . . . . . . . . . . . . . . . .17
4.5 Cascade settingsmenu . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.6 Diagnosismenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5 Eliminate fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.1 Status indicator on the individual installed or
higher-level cascade module . . . . . . . . . . . . . . . . . . . . .19
5.2 Status indicator on the lower-level cascade
module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
6 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation instructions for skilled labour
1 Key to symbols and safety instructions
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this document:
NOTICE indicates a situation that could result in damage to property
or equipment.
CAUTION indicates a situation that could result in minor to medium
injury.
WARNING indicates a situation that could result in severe injury or
death.
DANGER indicates a situation that will result in severe injury or
death.
Important information
Additional symbols
1.2 General safety instructions
These installation instructions are intended for a competent person.
Read the installation instructions (heat appliances, modules, etc.)
before installation.
Observe safety instructions and warnings.
Observe national and regional regulations, technical rules and
guidelines.
Keep a record of any work carried out.
Determined use
Use the product only to control heating systems with cascade
systems. In a cascade system, several heat sources are used to
achieve greater heat output.
Any other use is considered inappropriate. Any damage that may result
is excluded from liability.
Installation, commissioning and maintenance
Installation, commissioning and maintenance must only be carried out
by a competent person .
Never install the product in wet rooms.
Only install genuine spare parts.
Electrical work
Electrical work must only be carried out by qualified electricians.
Warnings in this document are identified by a warning
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and
seriousness of the ensuing risk if measures to prevent
the risk are not taken.
This symbol indicates important information where
there is no risk to people or property.
Symbol Explanation
Step in an action sequence
Cross-reference to another part of the document
List entry
List entry (second level)
Table 1
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit EMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit EMS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 4,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info