Climate 5000 MS – 6721830160 (2020/12)
1.2 General safety instructions
HNotices for the target group
These installation instructions are intended for
qualified persons who are skilled in dealing with
refrigeration engineering and HVAC technology and
also electrical systems. All system-relevant
instructions must be observed. Failure to comply with
instructions may result in material damage and
personal injury, including danger to life.
Before carrying out the installation, read the
installation instructions of all system elements.
Observe the safety instructions and warnings.
Follow national and regional regulations, technical
regulations and guidelines.
Record all work carried out.
HGeneral dangers posed by the refrigerant
This appliance is filled with refrigerant R32. If the
refrigerant gas gets into contact with fire, it may
generate toxic gas.
Thoroughly ventilate the room if refrigerant leaks
during the installation.
Check the tightness of the system following the
installation.
Do not to let any other substance than the specified
refrigerant (R32) into the refrigerant cycle.
HSafety of electrical devices for domestic use
and similar purposes
The following requirements apply in accordance with
EN 60335-1 in order to prevent hazards from
occurring when using electrical appliances:
“This appliance can be used by children of 8 years and
older, as well as by people with reduced physical,
sensory or mental capabilities or lacking in experience
and knowledge, if they are supervised and have been
given instruction in the safe use of the appliance and
understand the resulting dangers. Children shall not
play with the appliance. Cleaning and user
maintenance must not be performed by children
without supervision.”
“If the power cable is damaged, it must be replaced by
the manufacturer, its customer service department or
a similarly qualified person, so that risks are avoided.”
HHandover to the user
When handing over the air conditioning system,
explain the operation and operating conditions to the
operator.
Explain operation – with particular emphasis on all
safety-related actions.
Highlight the following points in particular:
Point out that modifications or repairs may be
carried out only by an approved contractor.
To ensure safe and environmentally compatible
operation, an annual inspection, and also
cleaning and maintenance if required, must be
carried out.
Point out the possible consequences (personal
injury and possible danger to life or material
damage) of not carrying out inspection, cleaning
and maintenance correctly, or omitting it
altogether.
Hand over the installation and operating
instructions to the user for safekeeping.
1.3 Notices regarding these instructions
The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2Product Information
2.1 Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2 Type overview
Depending on the outdoor unit, varying numbers of indoor units can be
connected:
Table 2 Outdoor unit appliance types
Unit type Quantity
Climate 5000 MS ... Connections Indoor units (max.)
14 OUE 2×6.35mm (1/4")
2×9.53mm (3/8")
2
18 OUE
21 OUE 3×6.35mm (1/4")
3×9.53mm (3/8")
3
27 OUE
28 OUE 4×6.35mm (1/4")
3×9.53mm (3/8")
1 × 12.7 mm (1/2")
4
36 OUE
42 OUE 5×6.35mm (1/4")
4×9.53mm (3/8")
1 × 12.7 mm (1/2")
5
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit-Bosch Climate 5000 Multi Split at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit-Bosch Climate 5000 Multi Split in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 24.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit-Bosch Climate 5000 Multi Split

Nefit-Bosch Climate 5000 Multi Split User Manual - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info