Operation and maintenance
17
Climate 5000 MS – 6721830161 (2020/12)
3 Operation and maintenance
CAUTION
Danger due to electric shock or moving parts
Disconnect the power supply before carrying out any maintenance
work.
Have any maintenance steps that are not listed here carried out by an
approved contractor.
You can find information on operating the indoor units in the
corresponding operating instructions.
3.1 Selecting the operation mode
If you are operating two units at the same time, both must be in the same
operating mode. Heating mode always has priority. If you set one unit to
heating mode, all other units can only be used in heating mode.
Example: if the first unit to be started is running in cooling or Fan Mode,
all other appliances can be switched on in any operating mode apart
from heating mode. As soon as one unit switches to heating mode, all
other appliances switch off and indicate a fault: "−−" appears in the
display or the Auto and ON indicator flash, the defrost indicator is off and
the timer indicator is permanently on.
3.2 Cleaning the unit and the remote control
NOTICE
Damage to unit due to incorrect cleaning!
Do not directly splash or pour water onto them.
Do not use hot water, thinner, abrasive powders or strong solvents.
Clean indoor unit and remote control by wiping them with a soft cloth.
Only have the outdoor unit cleaned by an approved contractor.
3.3 Method for cleaning the air filter
NOTICE
The air filter may deform in direct sunlight.
Do not expose the air filter to direct sunlight.
Clean the air filter every 2 weeks, and also before and after
decommissioning for longer periods.
Cleaning the air filter of the wall-mounted indoor units
Switch off the indoor unit.
Fold the top cover of the indoor unit up.
Push the air filter up and pull it out ( Fig. 5).
Take out the small air filters, if installed.
Clean the small air filters with a handheld vacuum cleaner.
Wash the large air filter with warm water and a mild cleaning agent
and dry in the shade.
Reattach the small air filter and the large air filter.
Cleaning the air filter of the built-in ducted indoor units
Switch off the indoor unit.
Pull out the air filter ( Fig. 6).
Wash the air filter with hot water and a mild cleaning agent and dry in
the shade.
Cleaning the air filter of the cassette indoor units
Open the air inlet grille ( Fig. 7).
Remove the air filter.
Wash out the air filter with hot water and a mild cleaning agent and
dry in the shade.
3.4 When re-commissioning after decommissioning for
an extended period
3.4.1 Maintenance before decommissioning for an extended
period:
Clean the air filter of the indoor and outdoor unit.
Leave the fan of the indoor unit running for approx. 24 h in Fan Mode
to allow the inside of the appliance to dry.
Switch off the indoor unit and disconnect it from the power supply.
Protect the unit from dust.
Check the outdoor unit at regular intervals. Contact customer service
or an authorised service engineer if a fault occurs.
3.4.2 Maintenance after a long period of non -use
Wipe the air inlet grille with a clean dry cloth so the indoor unit does
not blow out dust.
Make sure that the air inlet and air outlet are unobstructed and have
not been inadvertently adjusted.
Check all cables and connect the power supply.
If required, make sure that the air filter is installed.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit-Bosch Climate 5000 Multi Split at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit-Bosch Climate 5000 Multi Split in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 7.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit-Bosch Climate 5000 Multi Split

Nefit-Bosch Climate 5000 Multi Split Installation Guide - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish - 144 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info