780605
16
Zoom out
Zoom in
Previous page
1/64
Next page
Product information and main functions
Climate 5000 MS – 6721830161 (2020/12)
16
2 Product information and main functions
2.1 Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2 Unit components
Wall-mounted indoor unit - legend for Fig. 1:
[1] Air intake grille on rear
[2] Front cover
[3] Air purifying filter and air filter (behind)
[4] LCD display
[5] Vertical ventilation flap
[6] Horizontal ventilation flaps (behind)
Built-in ducted indoor unit - legend for Fig. 2:
[1] Air inlet
[2] Electric control box
[3] Air filter
[4] Air Outlet
Cassette indoor unit - legend for Fig. 3:
[1] Condensate pump (for draining condensate from the indoor unit)
[2] Condensate hose
[3] Display
[4] Return air inlet
[5] Air inlet
[6] Air Outlet
Outdoor unit - legend for Fig. 4:
[1] Fan cover
[2] Condensate hose, refrigerant line
[3] Connecting cable (to indoor unit)
[4] Stop valve
2.3 Functions
Protecting the air conditioner
Compressor protection: if the compressor was stopped, it can only
be restarted after a few minutes.
Anti Cold Air: the appliance is designed not to emit cold air in heating
mode if the heat exchanger of the indoor unit is in one of the following
three phases and the set temperature has not yet been reached:
if heating mode has just been started,
during de-icing,
when heating at low temperatures.
Defrosting: frost may form on the outdoor unit during heating mode
when the outside temperature is low and the humidity is high. Frost
can reduce the heating efficiency. When this happens, the unit ends
the heating operation automatically and starts defrosting. Defrosting
may take between 4 and 10 minutes, depending on how much frost is
on the outdoor unit.
Auto restart
The system stops immediately if a power failure occurs. The ON indicator
starts flashing when the power supply is restored. Product types with
auto-restart function resume operation automatically. Readjustment is
not required. Alternatively, you can bring the unit back into operation
manually by pressing the on/off switch on the remote control.
Changeover to Fan Mode when the set temperature is reached
When the preset temperature is reached, the compressor stops
automatically and switches to Fan Mode. The compressor only restarts
once the temperature in the room rises above the set temperature
(cooling mode) or falls below it (heating mode).
Heating mode
The outdoor unit generates heat in heating mode and releases it via the
indoor unit. Much higher heat losses occur in heating mode at very cold
temperatures. We recommend using an additional wall hung boiler if the
air conditioning system is not heating sufficiently.
2.4 Operating temperature range
Table 2
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
If the humidity is more than 80 %, condensation may form at the air
outlet. To prevent this, open the vertical ventilation flaps as wide as
possible (vertical relative to the ground) and set a high fan output.
Room temperature Outside temperature
Cooling 17 °C ... 32 °C −15 °C ... 50 °C
Heating 0 °C ... 30 °C −15 °C ... 24 °C
Dehumidifying 10 °C ... 32 °C −15 °C ... 50 °C
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Nefit-Bosch Climate 5000 Multi Split at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Nefit-Bosch Climate 5000 Multi Split in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 7.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Nefit-Bosch Climate 5000 Multi Split

Nefit-Bosch Climate 5000 Multi Split Installation Guide - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Turkish, Spanish - 144 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info