13 MENU: Toggle to view the available options such as LEVEL TRIM and
SAMPLE RATE options for BALANCED and SINGLE-ENDED input signal
as well as selections for SPEAKER COMPENSATION and POLARITY. These
menu options are accessed by pressing the MENU button and then
rotating the VOLUME control knob clockwise or counterclockwise to
select desired level or setting. Release the VOLUME knob when you
reach your preferred level or setting. The change will take eect after a
few seconds when the display returns to show the default information
(selected input and volume setting). Press MENU button again to select
another menu option.
LEVEL TRIM: Adjust the BALANCED or SINGLE-ENDED input signal level
from -9dB to 0dB or FIXED.
-9dB to 0dB: Increase or decrease the input signal level from -9dB
to 0dB. This attenuates the signal before the Analog-to-Digital (A/D)
Converter. If the analog input signal sounds distorted, the input
should be attenuated.
NOTE
Attenuating too much can reduce the potential resolution of the A/D
Converter.
FIXED: This setting should be selected when M2 is connected
to the output of a preamplier and is used primarily as a power
amplier. Output level is xed and the M2’s Volume Control is
bypassed. Adjust the level using the source signal’s preamplier
volume or input level control.
NOTE
VOLUME control is bypassed and cannot be adjusted when LEVEL TRIM
is set to “FIXED” setting. The corresponding VOLUME level (in dB) will not
appear in the VFD; what will be shown instead is “VOL FIXED”. Set LEVEL
TRIM to any other level except “FIXED” to adjust VOLUME control to
desired level.
SAMPLE RATE (48 kHz, 96 kHz, 192 kHz): Select the users
preference for sample rate of the A/D Converter. Higher sampling
rates allow for anti-aliasing lters to take eect further outside the
audible frequency range and are generally considered to sound
better, especially in the high frequencies. You may need to reduce
the sampling rate if you are using the Digital Processor Loop, as many
external devices will not operate at 96 kHz or 192 kHz.
SPEAKER COMPENSATION (2 Ohms, 4 Ohms, 5 Ohms, 6 Ohms,
7 Ohms, 8 Ohms, >8 Ohms): Digital impedance compensation lter
allows ne tuning of the top octave to match the speaker impedance.
This will result in perfectly at frequency response at 20 kHz. The
eect of this lter may not be audible* but it is measurable, and it
compensates for the small eect of the digital reconstruction lter that
eliminates the 288 kHz sampling frequency of the amplier.
*The exception may be some electrostatic speakers that have very low
impedance at high frequency. The lower the HF impedance, the greater
the deviation from at response.
POLARITY (POSITIVE, REVERSED): Allow compensation for
recordings that have reversed polarity.
Positive: A positive sine wave at the input remains positive at the
output.
Reversed: A positive sine wave at the input is negative (inverted) or
reversed at the output.
IMPORTANT NOTICE
For all of the above menu options, a chosen option or level setting will
not immediately take eect upon selection. There will be a slight delay or
pause before the corresponding action or response is realized.
RENAMING A SOURCE INPUT
A particular source input can be renamed according to your preference.
You can use up to 20 characters in renaming a source input. Below is the
procedure on how to rename a source input.
Example: Rename “DIGITAL OPTICAL 1” to “BD PLAYER”.
1 Press the front panel optical 1” button to select “DIGITAL OPTICAL
1” input. Then, press and hold the front panel optical 1” button until
“DIGITAL OPTICAL 1” is shown in the lower section of the VFD and with
“D” ashing (Note that “DIGITAL OPTICAL 1” is also shown at upper
section of the VFD).
2 Within 5 seconds, rotate the VOLUME control knob clockwise or
counterclockwise to select the rst character (“B” from the alphabetical
list). The ranges of characters available are 0-9, _ (space) and A-Z.
3 Press the front panel “loop button to select the character and at the
same time move on to the next character. Repeat steps 2 and 3 for
each character in sequence.
4 Complete the renaming process by pressing the front panel “menu”
button to save the new source input name.
NOTES
• Renamingofasourceinputcanonlybedoneusingthefrontpanelbuttons.
• Ifnochangeismadewithin5secondsorifthefrontpanelbuttonofthe
source input being renamed is pressed, the renaming process will be
automatically terminated with any renamed characters made not saved.
• Youcanterminatetherenamingprocessbypressinganyotherfront
panel buttons (except “loop, “menu” or the current source input being
renamed). The renamed characters at the time of terminating the
process will be saved.
IDENTIFICATION OF CONTROLS
FRONT PANEL
7
ENGLISHFRANÇAISESPAÑOLITALIANODEUTSCHNEDERLANDSSVENSKAРУССКИЙ
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for NAD M 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of NAD M 2 in the language / languages: English as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of NAD M 2

NAD M 2 User Manual - German - 14 pages

NAD M 2 User Manual - Dutch - 14 pages

NAD M 2 User Manual - French - 14 pages

NAD M 2 User Manual - Italian - 14 pages

NAD M 2 User Manual - Swedish - 14 pages

NAD M 2 User Manual - Spanish - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info