610978
14
Zoom out
Zoom in
Previous page
1/16
Next page
Electric Underfloor Heating14
8.0 Technical Data
Type Wattage
m
2
1 150W
1.5 225W
2 300W
2.5 375W
3 450W
3.5 525W
4 600W
4.5 675W
5 750W
6 900W
7 1050W
8 1200W
9 1350W
10 1500W
Heat Outputs
Amps
0.65
0.97
1.30
1.63
1.95
2.28
2.61
2.93
3.26
3.91
4.56
5.22
5.87
6.52
Ohm
353
235
176
141
117
100
88
78
70
59
50
44
39
35
Order type Programmable Floor
Temperature Controller
Supply voltage 230 V AC 50 HZ
(195 ... 253 V)
Temperature 10°C to 40°C; in 0.5°C
setting range steps
Temperature 0.1°C steps
resolution
Output relay NO contact
Switching current 10mA... 16(4)A AC*;
230 V~
Output signal PWM (Pulse Width
modulation) or ON/OFF
PWM cycle time adjustable
Hysteresis adjustable (ON/OFF only)
Minimum 10 Min
programmable time
Power consumption ~ 1,2 W
Accuracy of clock < 4 Min / year
Power reserve ~ 10 Years
Remote sensor F 193 720, length 4m,
can be extended up
to 50m
Ambient without condensation
temperature
- Operating 0°C … 40°C
- Storage -20°C … 70°C
Rated impulse 4 kV
voltage
Ball pressure test 115°C
Voltage and 230V, 0,1A
Current for the
purposes of
interference
measurements
Degree of IP 30
protection
Protection class II (see Caution)
of housing
Pollution degree 2
Software class A
Weight ~280 g
(with remote
sensor)
NB. For current > 14 A do not loop the N-wire through the controller, use a separate terminal.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson ELECTRIC UNDERFLOOR HEATING at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson ELECTRIC UNDERFLOOR HEATING in the language / languages: English as an attachment in your email.

The manual is 4,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info