13Electric Underfloor Heating
7.0 Electrical Connection
CAUTION: Maximum length of removed cable insulation 8mm.
42.550
17. 5
80.5
Sensor
LNN
230 V~ 50 Hz
L
N
Load
Fig. 26
Fig. 27
Connecting the Remote Sensor
CAUTION: The sensor is at mains voltage.
The MYSON Programmable Floor Temperature
Controller needs a remote temperature sensor.
This sensor should be mounted in such a way that
the temperature which has to be controlled can
be measured correctly. Lay sensor inside a
protective tube (simplifies replacement).
The sensor lead can be extended up to 50m by
using a cable and connections suitable for 230V.
Avoid laying sensor cable alongside power cables,
for example inside a conduit.
20 Ø 7.8
Connect according to Wiring Diagram (fig 26).
For flexible or solid wires 1 - 2.5mm
2.
CAUTION: DISCONNECT ELECTRIC CIRCUIT FROM SUPPLY.
Dimensions (mm)
Dimensions (mm)
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson ELECTRIC UNDERFLOOR HEATING at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson ELECTRIC UNDERFLOOR HEATING in the language / languages: English as an attachment in your email.

The manual is 4,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info