610978
3
Zoom out
Zoom in
Previous page
1/16
Next page
03Electric Underfloor Heating
1.0 General Information
The MYSON mat is manufactured from high
quality, durable materials. To guarantee that your
product functions optimally there are a few points
of attention which are described in the installation
manual. We can only offer you the full guarantee
if the mat is correctly installed in accordance with
the installation manual. Carefully read the
instructions prior to installation and ensure that
you have the correct tools and materials.
PLEASE NOTE: The electrical installation MUST BE carried out by a qualified electrician.
2
2
2
l
Before installing check if the heating mat is the
right size for the floor area to be heated and that
there is sufficient electrical capacity (Amps)
available. The mat should not be positioned over
expansion joints.
l
If multiple mats are installed in an area then a
shared power point can be installed so that only
1 power cable runs to the thermostat. Maximum
capacity of the thermostat is 16 Amps. The
thermostat should be installed by a qualified
electrician. The power supply must be turned off
during installation.
l
The MYSON mat consists of a heating cable of
8-9 Watts per metre that is equally distributed
and connected to a glass fibre net with an
inter-loop distance of approximately 70mm.
l
Each mat is tested at the factory and has a unique
inspection card. Every mat is tested at 4000 volt.
You must check the mat after each installation
phase, in order to know at which phase any
defect occurs (section 4.0).
l
The heating cable, attached to the grey glass
fibre net, must NOT be broken. The mats must
NOT be laid over each other and the heating
cables must NEVER cross each other. The cable
junction (where the power supply cable joins the
heating cable) is just within the heating mat and
is marked.
l
The mat has 1 connecting cable, which is 5
metres in length. The connector cable MUST
NOT be shortened by more than 3 metres, there
must therefore always be at least 2 metres of
connecting wire left. The power supply must be
turned off during installation.
l
The heating mat is 3 - 4 mm thick and must be
incorporated in an adhesive or screed suitable for
floor heating. Check the manufacturer’s data.
l
A distance from the wall of 100mm should
generally be adhered to. The mat may never be
installed under fixed objects like wall units,
kitchen units, baths or showers and must be able
to give off its warmth unimpeded.
l
The MYSON mat may only be incorporated into
the free floor/wall areas. As many bathrooms
consist mainly of a small free floor area the mat
may only be installed as supplementary heating.
Please contact your heating engineer who will
advise the heating requirement of the room.
l
The sensor MUST be installed in the middle of a
cable loop for optimal temperature registration.
Ensure that the sensor is installed well clear (min.
500mm) of hidden radiator and water pipes,
drains and electrical wiring.
l
The sensor MUST always remain in the sensor
pipe. Cap the end of the pipe to avoid the sensor
getting stuck during installation. If the sensor
ever needs to be replaced it can then easily
be removed.
l
A sufficiently strong and thick compression
resistant floor, with or without reinforcing, must
be applied on wood and insulation. If this is not
the case please contact Customer Services and
enquire about our other products.
l
The electric heating mat is guaranteed for 10
years. The thermostat is guaranteed for 2 years.
The guarantee does not apply to damage caused
by external factors and/or incorrect installation.
l
In compliance with the EU Directive
2006/66/EC, the button cell battery located on
the printed circuit board inside this product,
can be removed at the end of the product life,
by professional personnel only.
MAT THERMOSTAT
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myson ELECTRIC UNDERFLOOR HEATING at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myson ELECTRIC UNDERFLOOR HEATING in the language / languages: English as an attachment in your email.

The manual is 4,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info