In some cases, it can be difficult or impractical to install a wired sensor. For example, it may be the case that the
unit needs to be connected to a sub-board, rather than main consumer unit and two consumer units are in different
buildings.
The solution to is to install a clever device that enables the and
products to be installed without using wired CT sensors; instead, the CT sensor is
connected to .
The does not need batteries or a power supply the energy from the sensor is
harvested and used to transmit the measured signal to the or . This means
batteries or electrical wiring are eliminated!
Up to 3 CT sensors may be used with and it also supports 3-phase systems if three
sensors are connected.
Refer to the installation guide for details on installing and configuring for your system.
Only ONE Grid CT per phase (check for only one ~ symbol in Linked Devices Info).
Positioned to ‘see’ ALL import and ALL export current (i.e. always upstream of any junction box).
Must be on the same phase as the master device.
Arrow should point towards the consumer unit.
When using in 3-phase mode, the CT inputs correspond to the phase number (e.g. CT1 = Phase 1).
All harvi devices used in a 3-phase property must be set to 3-phase mode
Can be wired to ANY device in the network.
can be used to make ANY CT wireless
4
.
The CT cable can be extended up to 100m (must use twisted-pair cable e.g. one pair of CAT5). The CT cable
can also be shortened.
Can be clipped around two or more conductors feeding appliances of the same type (e.g. two Live cables
from two inverters that are on the same phase).
Can be in close proximity to other CTs.
Wires can be swapped in the device to reverse the direction of the readings (e.g. change import to export).
Can be grouped with other CTs of the same type so that the power reading is summed (e.g. east and west
solar Generation).
Can be used on the Neutral conductor in a single-phase installation (direction of arrow or wires must be
reversed).
Can be set to none in the menu if you want to exclude the reading.
4
Although CT’s connected to a cannot be used with Monitor Group option
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Myenergi Zappi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Myenergi Zappi in the language / languages: English as an attachment in your email.

The manual is 3.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info