SAVE THESE INSTRUCTION-This manual contains important instructions that should be
followed during installation and maintenance of the UPS and batteries.
Do not connect appliances or devices which would overload the UPS system (e.g. laser printers)
to the UPS output sockets.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be easily accessible
and close to the UPS system.
Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your computer) to
connect the UPS system to the building wiring outlet (shockproof outlet).
Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS system.
When installing the equipment, it should ensure that the sum of the leakage current of the UPS
and the connected devices does not exceed 3.5mA.
Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof
socket outlet) during operations since this would cancel the protective earthing of the UPS system
and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS output sockets or
output terminals block may be electrically live even if the UPS system is not connected to the
building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect the
mains.
Prevent no fluids or other foreign objects from inside of the UPS system.
The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified
maintenance personnel.
Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring
outlet), components inside the UPS system are still connected to the battery and electrically live
and dangerous.
Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify
that no current is present and no hazardous voltage exists in the terminals of high capability
capacitor such as BUS-capacitors.
Only persons are adequately familiar with batteries and with the required precautionary measures
may replace batteries and supervise operations. Unauthorized persons must be kept well away
from the batteries.
Caution - risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous
voltages may occur between the battery terminals and the ground. Before touching, please verify
that no voltage is present!
Batteries may cause electric shock and have a high short-circuit current. Please take the
precautionary measures specified below and any other measures necessary when working with
batteries:
remove wristwatches, rings and other metal objects
use only tools with insulated grips and handles.
When changing batteries, install the same number and same type of batteries.
Do not attempt to dispose of batteries by burning them. This could cause battery explosion.
Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It
may be toxic.
Please replace the fuse only with the same type and amperage in order to avoid fire hazards.
Do not dismantle the UPS system
Tower Installation
STEP 1
STEP2
STEP1
STEP2
STEP3
Set up the UPS
STEP 1: UPS input connection
STEP 5: Disable and enable EPO function
Keep the pin 1 and pin 2 closed for UPS normal operation. To activate EPO function, cut the wire
between pin 1 and pin 2.
STEP 2: UPS output connection
STEP 3: Communication connection: Communication ports includes
USB port RS-232 port Intelligent slot
STEP 6: External battery connection (for long-run models only)
Connect one end of external battery cable to UPS unit and the other end to battery box. Use supplied
battery detection wire in detection port of UPS unit and plug the other end to battery bank.
STEP 7: Turn on the UPS
STEP 4: Network connection
Network/Fax/Phone surge port
STEP 8: Install softwar
1. Go to the website: http://www.power-software-download.com
2. Click ViewPower software icon and then choose your required OS to download the software.
Button Operation
Button
Function
Button
Function
ON/Mute
Button
Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.
Mute the alarm: When the UPS is on battery mode, press and hold this button for at least
3 seconds to disable or enable the alarm system. But it’s not applied to the situations when
warnings or errors occur.
Up key: Press this button to display previous selection in UPS setting mode.
Switch to UPS self-test mode: Press and hold ON/Mute button for 3 seconds to enter UPS
self-testing while in AC mode, ECO mode, or converter mode.
Select Button
Switch LCD message: Press this button to change the LCD message for input
voltage, input frequency, battery voltage, output voltage and output frequency. It
will return back to default display when pausing for 10 seconds.
Setting mode: Press and hold this button for 3 seconds to enter UPS setting mode
when UPS is in standby mode or bypass mode.
Down key: Press this button to display next selection in UPS setting mode.
OFF/Enter
Button
Turn off the UPS: Press and hold this button at least 2 seconds to turn off the UPS. UPS will
be in standby mode under power normal or transfer to Bypass mode if the Bypass enable
setting by pressing this button.
Confirm selection key: Press this button to confirm selection in UPS setting mode.
OFF/Enter +
Select Button
Rack or Tower display switch: Press Select and OFF/Enter buttons simultaneously
for 3 seconds to change the display direction between Rack and Tower screens.
1. Programmable outlets: connect to non-critical loads.
2. Output receptacles: connect to mission-critical loads.
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery connector (only available for L model)
SAFETY CAUTION
Installation
Real Panel
User Manual
PM 1500/2000/3000 NetGuard LCD Line Interactive IEC Versi on: 1 .0
EN
Operation
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mustek PowerMust 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mustek PowerMust 3000 in the language / languages: English, German, French, Italian, Polish, Portuguese, Finnish as an attachment in your email.

The manual is 1,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info