Seite 14
x If these batteries are mistreated, there is a danger of
fire, explosion, burns and chemical burns. Suitable
extinguishing agents: water, CO2, sand.
x Escaped electrolyte is corrosive!
Do not allow it to contact your skin or eyes. In an
emergency wash the affected area with copious
amounts of water and seek the help of a doctor
immediately.
8.4. Charging the transmitter battery
!
Never connect the TX without battery to a
charger!
Chargers can supply high output voltages if no
battery is connected. This voltages can cause dam-
ages in the transmitter.
!
Rapid charging with 1.5 A max.!
!
Charging with mains chargers or
12V-chargers for max. 8 cells
The battery can remain installed in the TX for
charging. Connection to the charger is made via
the charging socket on the back of the transmitter
(Î 7.2.). Use only genuine MULTIPLEX charge
leads (e.g. transmitter charge lead with banana
plugs # 8 6020). For details of other charge leads
and battery chargers please refer to the current
MULTIPLEX main catalogue.
!
Charging with 12V-chargers
for more than 8 cells
Never charge via the charging socket! Unplug
the battery from the electronics board and use the
TX battery direct charge lead # 8 6021.
The battery management can only work correctly
with a permanent connection (even if the transmit-
ter is switched off) between battery and
electronics board to measure into (charging) or out
of (operation) the battery. Chargers for more than
8 cells need voltage converters producing high
voltages, which can damage the transmitter elec-
tronics.
Full capacity and performance
NiMH batteries only produce maximum performance
after a series of charge/discharge cycles (~5 cycles). The
first charge/discharge cycles should be carried out at
0.1CA (150 mA). Don’t fast-charge the pack until you
have done this.
What means C in charging advices?
C is the charging current, which supplies 100% of its
nominal capacity to a battery within 1 hour. This is a
current of 1500 mA for the 1500 mAh battey of the
ROYALevo. Charging with this current is named 1-C-
charging. This current can be derived from the nominal
capacity in mAh (or Ah) by just removing the letter “h”.
Standard charging
This means that the pack is charged at a current within
the range 0.05 to 0.2 C (75 mA to 300 mA).
The charge time is then calculated from the following
formula:
][
][
][
mArentCharge cur
mAhCapacity
heCharge tim
Fast charging
This means that the pack is charged at a current within
the range 0.5 to 1 C (750 mA to 1.5 A). The charging is
finished by the automatic cut-off.
!
Timer-controlled charging is not permissible!
!
Important with fast charging:
The charger must be designed to cope with NiMH
batteries, i.e. Delta Peak termination sensitivity < 5
mV/cell, or temperature-controlled termination at
> 0.8°C/min.
Trickle charging
This means that the pack is charged at a current within
the range 0.03 CA to 0.05 CA (45 to 75 mA). Automatic
chargers generally switch over to this mode of charging
when the fast charge phase is concluded. After max. 20
hours trickle charging must be stopped.
This is the correct method of charging:
1. Switch off the transmitter
2. Switch on the battery charger designed for NiMH
batteries (see left column 8.4.) and connect the
charge leads.
3. Check polarity:
Red plug = positive terminal (+)
Blue/black plug = negative terminal (-)
Connecting the charger with reversed polarity
may ruin the battery!
(excessive heat, escape of corrosive electrolyte,
bursting of cells)
4. Connect the charge lead to the transmitter
5. Select the charge current (max. 1.5 A); alternatively
set the current after starting the charge process
Automatic fast chargers:
Use manual current selection! If the fast charger
should interrupt the charge process prematurely,
reduce the charge current and start again.
6. Check the battery temperature regularly during the
charge process
7. Disconnect the transmitter from the charger at the
end of the process.
8. When you have charged the battery enter the
charged-in energy in the menu L Transmitter,
Batt. charge (8.1.3. a.).
Note:
The development of rechargeable batteries continues
apace, just like other technical components. We there-
fore reserve the right to supply different battery packs
as standard in our transmitters, in order to keep the
equipment abreast of current standards.
8.5. Maintaining and storing
the transmitter battery
Always store NiMH batteries in the fully charged state.
This avoids the danger of deep-discharge.
Store NiMH batteries at a temperature between 0°C and
30°C, in dry conditions, and out of direct sunshine.
Charge unused NiMH batteries every 3 months. This
compensates for the natural self-discharge rate, and
again prevents deep-discharge.
If you have to store a battery for a long period, we rec-
ommend that you balance the cells by giving the pack
several charge/discharge cycles. Protracted storage may
reduce the pack’s usable capacity.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Multiplex ROYALevo9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Multiplex ROYALevo9 in the language / languages: English as an attachment in your email.

The manual is 3,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Multiplex ROYALevo9

Multiplex ROYALevo9 User Manual - German - 58 pages

Multiplex ROYALevo9 User Manual - Dutch - 110 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info