744324
13
Zoom out
Zoom in
Previous page
1/19
Next page
24
25
DK ENG
How to position the bae and access bae
Make sure that the upper bae plate (2) is located into
its correct position. It should be placed on top of the rear
(xed) bae section and secured into position against
the 2 upstanding cast lugs. (See diagram).
Note: The access bae (3) must always be tted
when the stove is in use, as it not only assists the
combustion process, but also gives essential pro-
tection to the stove’s top plate.
1.7 Connecting the stove to a masonry chimney
A wall sleeve should be bricked securely into the wall of the chimney at the appropriate height
and the stovepipe inserted centrally. The pipe must not extend into the actual chimney open-
ing, but rather must reach only to the inside of the chimney aperture. The gap between the
stovepipe and sleeve must be sealed using glass bre packing rope.
Only use stovepipe components that comply to National and Local Building Regulations.
1.8 Connecting to a stainless steel insulated chimney system
If your installation involves taking the chimney straight up and through the ceiling, you must
comply with National, Local Building Regulations or ue manufacturers instructions concern-
ing clearances to combustible materials such as walls, oor joists and ceilings. The joint be-
tween the stove ue collar and the stovepipe must also be sealed using glass bre rope. It
is important that the insulated ue system is properly supported both at ceiling level and at
roof level.
THE STOVE MUST NOT BEAR THE WEIGHT OF THE CHIMNEY SYSTEM (See chimney man-
ufacturer’s instructions). Excessive weight on the stove will inhibit expansion and could lead
to damage of the stove top. Damage caused to the stove in this way would not be covered by
the manufacturers guarantee.
In the event that a chimney re occurs resulting from faulty operation or prolonged use of
damp wood fuel, close the air vents completely and contact your local re department im-
mediately.
Be aware of the following:
Cleaning procedure: Discuss this with chimney sweep or qualied installer prior
to or during the stove installation
Chimney draft: If the chimney draft is naturally poor it is better to install the ue from
the top of the stove so as to minimise any internal resistance of the ue gases.
Avoid having any more than 2 bends in the ue system and limit the length of the
oset between bends.
Fresh air supply
A wood-burning stove requires air for combustion. As a result, ring a wood-burn-
ing stove will help create a healthy climate in your house. If the house is very tightly
sealed, and particularly if there is a cooker hood or ventilation system in the house, it
may be necessary to install an air grate in the room in which the wood-burning stove
is installed. Otherwise there may not be enough draught in the chimney, which may
result in the stove not being able to burn properly, and smoke may come out of the
stove when the re door is opened.
If it is necessary to install air grates, they must be positioned so that they cannot
be obstructed.
1.9 Draft conditions
If smoke spillage occurs when the re door is opened, it is probably due to poor chimney
draft. This type of stove requires at least 12 pa of chimney draft to achieve satisfactory com-
bustion and smoke spillage prevention. However, in cases where the stove door is opened
too vigorously you could expect that slight smoke spillage may occur. The ue gas tempera-
ture at the rated output is 218˚ C relative to 20˚ C.
If you have any doubts, you may want to have your installer measure the draft in the chimney.
Draught
The draught in the chimney is the result of the dierence between the high tempera-
ture in the chimney and the cooler temperature outside. Other factors that determine
whether sucient negative pressure can be produced to create a draught include the
length and insulation of the chimney, and wind and weather conditions.
The draught will be reduced when:
- The temperature dierence is too low, e.g. in connection with a poorly insu-
lated chimney.
If the chimney is cold, it may help to light (burn up) a rolled-up newspaper in
the chimney’s cleaning door.
- The outside temperature is too high, e.g. during the summer.
- There is no wind.
- The chimney is not tall enough, with the result that it sits in the lee of the roof
surface or tall trees.
These conditions are also associated with the greatest risk of smoke coming
back down the chimney.
- Air is entering the chimney in undesired places, e.g. through cracked joints or
leaks in the cleaning door or the ue pipe.
- Unsealed, unused replaces are connected to the chimney.
- The ue pipe and chimney are clogged up with soot due to inadequate cleaning.
- The house is too tightly sealed (please see the section on Fresh air supply).
A good draught is achieved when:
- There is a big dierence between the temperature in the chimney and outside,
i.e. when the need for heating is greatest.
- The weather is clear and there is a good wind.
- The chimney is of the proper height, i.e. Minimum 4 metres above the stove,
and clear of the spine of the roof.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso 3100 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso 3100 series in the language / languages: English, Danish as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morso 3100 series

Morso 3100 series Usermanual and installation guide - German - 11 pages

Morso 3100 series Usermanual and installation guide - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info