On the oor
National and Local Building Regulations must again be observed when considering the type,
thickness and area of the hearth to be used in the installation. The hearth temperature under
safety test was less than 65°C.
One should of course always make certain that the underlying oor surface can bear the
weight of the stove.
Clearances to Furniture
The clearance requirement from the stove to any furniture should be no less than 800 mm. It
is always necessary to assess whether or not any furniture or other objects situated close-by
can be aected by heat, i.e. dried out.
The distance to any combustible material in front of the stove is minimum 800 mm.
The surface of a wood burning stove gets extremely hot when used and therefore special
attention to safety is paramount, especially where children or the inrm are present.
The stove is equipped with a removable stainless steel handle; for safety reasons it should
be removed during use, especially where children are nearby.
1.5 The chimney
Only if National or Local Regulations permit are you permitted to connect a stove into a chim-
ney that is shared by another appliance. YOU MUST be aware of any applicable Regulations
in this respect.
The wood-burning stove must never been connected to a chimney to which a gas-burning stove
or appliance is connected. An ecient modern stove places heavy demands on the chimney, and
you should have the chimney regularly swept and inspected by your approved chimney sweep.
The cross-sectional area of the chimney (at its narrowest point) must comply with National and
Local Building Regulations. Generally, the area needed for a Morsø wood-burning stove installa-
tion should measure at least 175 cm2 (150 mm diameter). Exceptions to this are: Smoke Exempt
Morsø stoves tted with a 125mm diameter ue collar. These can be connected to a chim-
ney system or liner with a minimal cross sectional area of 123 cm² (125mm diameter)
An over-sized chimney is generally hard to keep warm and results in poor draft. In cases where
there is an oversized masonry chimney, it is recommended that the chimney be lined using an
appropriate chimney lining system with the correct internal diameter. With respect to the chim-
ney termination, all chimneys should terminate in accordance with National and Local Building
Regulations.
Note that National and Local Regulations also apply with regard to the placement of chim-
neys and ues in connection with thatched roofs. See the section on Draft Conditions, 1.9.
The chimney or ue system must be equipped with access doors for inspection and clean-
ing. The size of the cleaning door in the chimney must at least equal to that of the cross-
sectional area of the chimney. In the event that a chimney re occurs resulting from faulty
operation or prolonged use of damp wood fuel, close the air vents completely and contact
your local re department immediately.
1.6 Fluepipe connections
The Stove comes ready prepared to accept an outside air-box kit, for markets where national
or local authorities require it. The outside air-box kit is ordered separately – Product Code:
54362021, detailed tting instructions are included within the kit.
The stove is supplied with a factory tted ue collar (1), this is tted to the top plate. A round
cast iron blanking plate covers the rear ue outlet (behind the rear heat shield). Where a
rear ue installation is required, simply knock out the top steel plate in the rear heat con-
vection panel. This is best done by applying gentle hammer taps immediately onto the small
”bridges” in the circular cut-outs. Once the knock-outs have been removed unbolt the cast
iron blanking plate and install it into the top of the stove. The ue collar can then be bolted
over the rear ue outlet using the bolts and clamps provided.
The cast iron blanking plate can also function as an extra clean-out access whilst perform-
ing the annual cleaning service of the stove and chimney.
Minimum distances from ammable material:
Type of stove Behind the stove
(A)
To the sides of
the stove (B)
Above the
stove
45° corner (C)
Morsø 3112/3116
radiation
200 mm 600 mm 600 mm 600 mm
Morsø 3142
convection with
uninsulated ue
200 mm 400 mm 600 mm 200 mm
Morsø 3142
convection with
insulated ue
50mm 300 mm 600 mm 100 mm
C
C
45°
Min. afstand til brandbar hjørnevæg for Morsø 3142
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:10
Afstand til hjørnevæg
Distance to Corner wall
Morsø 3142
RSV
06.10.2009
A4
Dimension Skecth
Date of print: 07-10-2016
C:\Users\tol\Documents\TempSWBackupDirectory\AutoRecovery\AutoRecover Of Afstand til hjørnevæg.SLDASM
3100-119 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Side 3 of 6
B
A
Min. afstand til brandbar hjørnevæg for Morsø 3142
Revisions
Rev.
Sign.:
Title:
Drawing no.:
Dim. without indication of margin acc. to DS/ISO 2768-1 m
1:10
Afstand til hjørnevæg
Distance to Corner wall
Morsø 3142
RSV
06.10.2009
A4
Dimension Skecth
Date of print: 07-10-2016
C:\Users\tol\Documents\TempSWBackupDirectory\AutoRecovery\AutoRecover Of Afstand til hjørnevæg.SLDASM
3100-119 a
Itemno.:
This drawing is Morsø Jernstøberi A/S' property and must not be sold, lended or copied without any written authorization from the company.
Material:
Weight:
Model no.
Drawingtype:
Location of file:
Scale:
Format:
Released:
Construction:
Date:
Side 2 of 6
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso 3100 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso 3100 series in the language / languages: English, Danish as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morso 3100 series

Morso 3100 series Usermanual and installation guide - German - 11 pages

Morso 3100 series Usermanual and installation guide - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info