1.8 Draft conditions
If smoke spillage occurs when the re door is opened, it is probably due to poor chimney
draft. This type of stove requires at least 12 pa of chimney draft to achieve satisfactory com-
bustion and smoke spillage prevention. However, in cases where the stove door is opened
too vigorously you could expect that slight smoke spillage may occur. The smoke gas tem-
perature at the rated output is 257˚ C relative to 20˚ C.
If you have any doubts, you may want to have your installer measure the draft in the chimney.
Draft conditions
The chimney’s draft is the resulting eect within the ue caused by the dierence in
temperature within the ue and the cooler temperature outside. Other factors that
can inuence the level of draft include the length of the ue, insulation of the chim-
ney, adverse weather conditions or tall buildings or trees nearby the ue terminal.
Poor draft occurs when:
- The atmospheric temperature dierence is too low, e.g. a poorly insulated chimney.
If the chimney is excessively cool, it may help to ‘prime’ the ue before the re is lit.
Just place a screwed-up sheet of newspaper in the ue-ways of the stove and ignite.
- The outside temperature is too high, e.g. during the summer months.
- There is no air movement (wind) outside.
- The chimney is not tall enough, with the result that the terminal sits in the lee of
the roof surface or in the vicinity of tall trees or neighbouring buildings. These
conditions are also associated with downdraft where the ue gases are pushed
back down the chimney.
- Flue draft is diluted by residual air entering the chimney, e.g. due to inadequate
ue-pipe joints or leaks at the cleaning door or ue collar.
- Unsealed, unused replaces are connected to the chimney.
- The ue is blocked, e.g. by soot, due to inadequate cleaning, loose debris or even
a birds nest.
- The house is too tightly sealed (see section on Fresh air supply).
A good draft is achieved when:
- The temperature dierence between the chimney and outside is high. This also
applies during ring, when the need is greatest.
- The weather is clear and there is a good wind.
- The chimney is of the proper height, i.e. minimum 4 meters over the stove and
the termination adequately clear of the roof line.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morso 2B Classic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morso 2B Classic in the language / languages: English, Danish as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morso 2B Classic

Morso 2B Classic Usermanual and installation guide - German - 16 pages

Morso 2B Classic Usermanual and installation guide - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info