Self clean
When the boiler requires descaling, the descale
button (19) will illuminate. When this happens, the
boiler must be descaled. The button’s light will go
out only after the scale has been removed.
1Unplug the appliance from the mains outlet and
leave to cool for two hours.
2Lock the iron (11) in place on the base unit (14).
See ‘Storing the steam iron’ on page 10.
3Remove the detachable water tank (3) to prevent
water spillage and upturn the steam generator.
This reveals the boiler screw (28) on the
underside of the base unit.
4Remove the boiler screw by unscrewing it
anti-clockwise.
WARNING: Never remove the boiler screw
when the steam generator is hot.
5
Remove the boiler tube (26) and the attached
boiler tube attachment (24) from their storage
position.
6Push the boiler tube attachment (24) firmly into
the hole where the boiler screw was removed
from. Ensure the boiler tube (26) is sitting within
the boiler tube crevice (27).
7Turn the steam generator back over so the iron
(11) is uppermost.
8Fill the detachable water tank and replace it back
into the base unit (14).
Never pour any descaling solution or any other
chemicals into the water tank. This will
damage the product. Only use clean water.
9Place the front end of the steam generator
securely over a sink so the boiler tube (26) drops
down into the sink. Ensure the boiler tube is not
squashed between the steam generator and the
edge of the sink.
10 Plug the appliance back in at the mains and turn
the power on.
11 Press and hold the descale button (19) and the
steam trigger (4) at the same time for one
second. A beep will be heard and the descale
button will begin to flash. The steam generator
will commence self-cleaning and scale and water
will begin to flow through the boiler tube into the
sink. The process will take around two minutes to
complete. When finished, three beeps will be
heard, the descale button’s light will extinguish
and the appliance will shut off automatically.
Maintenance
28
24
26
27
26
24
26
RN333200 MUK Rev1.qxp_IB 11/04/2018 17:16 Page 9
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morphy Richards 333201 - Speed Steam at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morphy Richards 333201 - Speed Steam in the language / languages: English as an attachment in your email.

The manual is 2.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info