During normal operation the “burner on” indicator (E) in the Boiler Controls diagram) will remain
illuminated when the burner is lit.
Note: If the boiler fails to light after five attempts the fault code “L-2” will be displayed. Refer to the fault
finding section on page 8 of this user manual.
Preheat
Pre-heat is enabled if the pre-heat indicator (F) in the Boiler Controls diagram is visible. To switch pre-
heat on or off move the DHW/Pre-heat control knob (B) fully clockwise and then return it to the required
DHW temperature setting.
Reset Procedure
To reset boiler after a fault has been detected, turn the mode control knob (A) fully clockwise to the reset
position and immediately turn knob back to required setting. The boiler will repeat the ignition sequence if
heating or domestic hot water is required. If the boiler still fails to light consult a qualified and competent
Gas Installer.
Winter conditions - CH and HW required.
Ensure the mode control knob (A) is set to winter ( )
If heat is demanded by the optional room thermostat and/or mechanical 24 hour timer the boiler will fire
and supply heat to the radiators but will give priority to DHW if any tap or shower is used.
Summer conditions - HW only required.
Set the mode control knob (A) to summer ( ).
Turn the CH control knob (C) fully anti-clockwise.
Note. The pump will operate briefly as a self-check once every 24 hours, regardless of where the control
knobs are positioned.
Domestic Hot Water Temperature Control
The DHW temperature is limited by the boiler controls to 64
o
C maximum. This will only apply when a
low flow rate through the boiler occurs. A more typical temperature is 45° C but this can be increased
by turning the DHW temperature control knob (B) to max and reducing the flow of water from the hot
outlet.
Central Heating Temperature Control
The radiator temperature is adjustable between 80
o
C and 45ºC via the CH control knob (C).
The boiler is a high efficiency combination boiler which is most efficient when operating in condensing
mode. The boiler will operate in condensing mode if the CH control knob (C) is set to the “e” position
(economy mode). This control knob should be turned fully clockwise in very cold weather.
To shut down the boiler
Turn the mode control knob (A) to OFF
To relight the boiler
Repeat the procedure detailed earlier in ‘To light the boiler’.
4


Need help? Post your question in this forum.

Forumrules
1

Forum

morco-gb24

Reset search

  • How can you tell what the temperature is on the boiler ? Submitted on 7-2-2022 at 14:04

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco GB24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco GB24 in the language / languages: English as an attachment in your email.

The manual is 0,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Morco GB24

Morco GB24 User Manual - English - 36 pages

Morco GB24 User Manual - Dutch - 10 pages

Morco GB24 User Manual - French - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info