section 5 - installation instructions
5.1 BOILER PACKAGING
The boilers are supplied in different packagings:
• Boiler
• FlueSystem(separate)
• HardwarePack(separate)
5.2 FITTING/MOUNTING THE BOILER
Decidewheretheboileristobexedonthewall,takinginto
account installation requirements detailed in previous section.
1. Screw the wall mounting plate to the wall choosing one of the
two sets of slots in left and right bank. Ensuring that at least
oneofthescrewsisttedintoatopslot.
2. Lift the boiler onto the wall mounting plate, locating it over the
two tabs.
Note. If present, remove the bottom end support packaging
and ensure all plastic plugs are removed from CH & DHW
connections.
5.3 WIRING INSTRUCTIONS
WARNING: THIS APPLIANCE MUST BE EARTHED
Connections must be made in such a way that allows complete
isolation of the electrical supply, e.g. double pole switch with
3mm contact separating in both poles.
N
L
N
ROOM
STAT/
TIMER
Room
Stat
230VAC Feed
230VAC Return
5.4 INTERNAL WIRING
Theboilerhasbeenpre-ttedwitha3ampfusedapproved
moulded3pinandyingleadforusewith230V50Hz.
If the supply cord is damaged, it must be replaced by the
manufacturer,itsserviceagentorsimilarlyqualiedpersonsin
order to avoid a hazard.
The plug should be used with an
unswitched/shuttered socket outlet
complying with BS1363.
Theboilercomespre-ttedwith
a link wire between the room
thermostat/Timer connections on
the terminal strip. This creates a
permanent call for heat and must
be removed when adding a room
thermostat.
ROOM THERMOSTAT - WIRING
Totaroomthermostatproceedasfollows:
1. Ensure that the electrical supply to the boiler is isolated before
proceeding.
2. Removethetwoscrewsbeneaththeaponthefrontofthe
boiler and lower the front panel.
3. Removethepre-ttedlinkwirebetweentheRoomstat/timer
terminals.
4. Pass the cable through a grommet, secure with the cable
clamp and connect the room stat as shown in the diagram
below.
5. If room stat has a neutral connection, connect this to terminal
N (load) in the fused spur.
6. Carry out all necessary electrical checks.
7. Raise the front panel and relocate the two screws under the
smallap.
8. Check operation of room stat if possible.
Example of fixing
4
Cable
Clamp
14


Need help? Post your question in this forum.

Forumrules
1

Forum

morco-gb24-series-ii

Reset search

  • We have this Boiler fitted in our Caravan and not had a trouble till we had the boiler serviced since then the boiler will deal with the hot water but if you put it onto timer for the central heating the boiler comes in and when it gets to temperature goes out but then when the temperature drops the boiler does not come back in and shows L-2 which means it’s locked out please advice what can be the trouble thankyou Submitted on 10-11-2021 at 19:52

    Reply Report abuse
  • Je voudrais savoir pourquoi s affiche sur l écran de contrôle F 9 qui clignote. Et pas d eau chaude. Submitted on 29-6-2021 at 18:11

    Reply Report abuse
  • Hot water working but no heating and no fault codes Submitted on 12-4-2021 at 18:39

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco GB24 Series II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco GB24 Series II in the language / languages: English as an attachment in your email.

The manual is 6,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info