The Fagor MORCO FEB-24ED 3 is a wall hung,
room sealed, fan assisted, microprocessor con-
trolled fully modulating gas combination boiler for
providing both central heating and domestic hot
water. It is particularly suitable for Caravan Holiday
Home and Park Home use. Maximum heat output in
either heating or hot water mode is 23.7.kW (80.840
Btu/h), and priority is always given to the supply of
hot water.
NOTE: The central Heating power is factory set at
70% of its maximum.
The appliance is supplied with a standard concentric
duct and wall terminal, however additional
extension kits, vertical
kit are available as
optional extras.
The appliance is intended for use with sealed central
heating systems and is supplied for use with
propane gas.
The appliance includes the following components:
Induced draught fan for the extraction of combus-
tion products and induction of combustion air.
Modulating gas valve with double safety valves
Circulation pump with manual anti-seizure device
Central heating expansion vessel.
air pressure switch . Prevents the boil-
er
if there is insu cient air supply due to a fault
or blockage.
Water pressure switch. Prevents the boiler ring if
there is less than 0.5 bar in the system.
Thermistors (NTC) There are two thermistors
for automatic control of the domestic hot water and
the central heating
temperature.
Safety thermostat Shuts down the boiler in the
event of overheating. Resets after a few minutes
cooling
Electronic controls, incorporating the following fea-
tures:
- Temperature selection for central heating from
between 60 to 85°C (Pre-set between 40º to 60ºC for
under
heating).
- Temperature selection for domestic hot water from
between 35 to 60°C.
- Continuous modulation of the gas valve.
- Flame control by ionisation
- Ignition control
- Anti-frost control in the central heating circuit.
- Anti - seizure of the pump.
2.- GENERAL SPECIFICATIONS
Schematic diagram- Hydraulic circuit
1.- Expansion vessel
2.- Pump with Automatic air bleed
3.- Water pressure switch
4.- Central heating thermistor return
5.- Central heating thermistor
6.- Three way valve
7.- Overheat thermostat
8.- Air pressure switch
9.- Venturi
10.- Fan
11.- Sealed air box
12.- Copper heat exchanger
13.- Combustion chamber
14.- Ignition electrode
15.- Burner
16.- Flame sensing electrode
17.- Modulating gas valve
18.- Gas inlet
19.- Hot Water outlet
20.- Plate heat exchanger
21.- C.H
22.- Cold water inlet
23.- C.H return
24.- Pressure relief valve
25.- Automatic By-pass
26.- Expansion vessel valve
27.- Draining valve
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Morco FEB-24ED at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Morco FEB-24ED in the language / languages: English as an attachment in your email.

The manual is 3,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info