15
5.8 INPUT TYPE
The input type defines the character of the additional inputs IN1 and IN2.
This can be Normally Open (NO) or Normally Closed (NC). If an input is set
to "NO", the alarm will be triggered as soon as the terminals of the input are
closed. If the input is set to NC, the alarm is triggered when the connection
between the input terminals is broken. The default input type is set to "NO".
5.9 POWER FAILURE MESSAGE
If the Mobeye MiniPir is supplied with external power and the power fails, it
can send alarm messages. If the setting is "OFF", no message is sent. In the
default setting “ALARM”, notifications are sent to the set contacts.
5.10 POWER FAILURE DELAY TIME
To avoid false alarms caused by short power failures, a power failure delay
time can be set. This defines the time between the initial power failure and
the alarm notification. If the power is restored within the delay time, no
alarm is sent. The time can be set between 0 and 999 minutes. As default,
the delay time is set to "0".
5.1 NOTIFICATION TO PRIVATE EMERGENCY CENTER
The Mobeye MiniPir can send the reports to a control room using the
standard SIA DC09 protocol. This requires the use of the Mobeye
SIM/Portal. Contact Mobeye for information.