599485
13
Zoom out
Zoom in
Previous page
1/15
Next page
13
BEFORE CONTACTING THE SERVICE REPRE-
SENTATIVE, CHECK THE FOLLOWING AGAIN
Question
The air conditioner cannot
be operated for about 3
minutes when restarted.
Cracking sound is heard.
The air from the indoor unit
smells strange.
The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.
The sound of water flowing
is heard.
The sound as burbling is
heard.
The room cannot be cooled
sufficiently.
Mist is discharged from the
air outlet of the indoor unit.
Mechanical sound is heard
from the indoor unit.
The swing operation of the
HORIZONTAL VANE is
suspended for about 15
seconds, then restarted.
Answer (not a malfunction)
This protects the air conditioner according to
instructions from the microprocessor. Please
wait.
This sound is generated by the expansion/
contraction of the front panel, etc. due to change
in temperature.
The air conditioner may suck in an odor adhering
to the wall, carpet, furniture, cloth, etc. and blow
it out with the air.
When the outside temperature is low, the fan
may not operate to maintain sufficient cooling
capacity.
This is the sound of refrigerant flowing inside the
air conditioner.
This is the sound of condensed water flowing in
the heat exchanger.
This is the sound of the heat exchanger
defrosting.
This sound is heard when the outside air is
absorbed from the drain hose in turning on the
range hood or the ventilation fan and that makes
water flowing in the drain hose spout out. This
sound is also heard when the outside air blows
into the drain hose in case the outside wind is
strong.
When a ventilation fan or a gas cooker is used
in a room, the cooling load increases, resulting
in an insufficient cooling effect.
When the outside air temperature is high, the
cooling effect may not be sufficient.
The cool air from the air conditioner rapidly cools
moisture in the air inside the room, and it turns
into mist.
This is the switching sound in turning on/off the
fan or the compressor.
This is for the swing operation of the
HORIZONTAL VANE to be performed normally.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
Question
The air conditioner cannot
be operated.
All LED lamps on the indoor
unit are blinking.
The horizontal vane does
not move.
The room cannot be cooled
or heated sufficiently.
The air from the indoor unit
smells strange.
The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the
remote control signal.
When a power failure
occurs.
Check points
Is the breaker turned on?
Is the fuse blown?
Is the ON timer set? (Page 9)
Is the horizontal vane attached to the indoor unit
correctly? (Page 12)
Are the horizontal vane and the vertical vane
attached to the indoor unit correctly? (Page 12)
Is the fan guard deformed?
Is the temperature setting correct? (Page 7)
Is the filter clean? (Page 10)
Is the fan of the indoor unit clean? (Page 12)
Are there any obstacles blocking the air inlet or
outlet of the indoor or outdoor unit?
Is a window or door open?
Is the filter clean? (Page 10)
Is the fan of the indoor unit clean? (Page 10)
Are the batteries exhausted? (Page 5)
Is the polarity (+, -) of the batteries correct?
(Page 5)
Are any buttons on the remote controller of other
electric appliances being pressed?
Does the air conditioner start operating again?
If the air conditioner had operated before the
power failure, as these models are equipped with
an auto restart function, the air conditioner
should start operating again. (Refer to
Description of AUTO RESTART FUNCTION on
page 6.)
Question
The air flow direction
changes during operation.
The direction of the
horizontal vane cannot be
adjusted with the remote
controller.
Water leaks from the
outdoor unit.
White smoke is discharged
from the outdoor unit.
Air does not blow out soon
in the heating operation.
The operation is stopped
for about 10 minutes in the
heating operation.
Hissing sound is sometimes
heard.
The room cannot be heated
sufficiently.
In a multi-unit system, the
indoor unit which is not
operating becomes warm
and a sound, similar to
water flowing, is heard from
the unit.
The air conditioner starts
the operation only with the
main power turned on,
though you do not operate
the unit with the remote
controller.
Answer (not a malfunction)
When the air conditioner is operated in COOL
or DRY mode, if the operation continues with air
blowing down for 1 hour, the direction of the air
flow is automatically set to position (1) to prevent
condensed water from dropping.
In the heating operation, if the air flow
temperature is too low or when defrosting is
being done, the horizontal vane position is
automatically set to horizontal.
During COOL and DRY operations, pipe or pipe
connecting sections are cooled and this causes
water to condense.
In the heating operation, the defrosting operation
makes water frozen on the outdoor unit melt and
drip down.
In the heating operation, water condensed on
the heat exchanger drips down.
In the heating operation, vapor generated by the
defrosting operation looks like white smoke.
Please wait as the air conditioner is preparing
to blow out warm air.
Defrosting of the outdoor unit is being done
(Defrosting operation).
Since this is completed in 10 minutes, please
wait. (When the external temperature is too low
and humidity is too high, frost is formed.)
This is the sound when the flow of refrigerant
inside the air conditioner is switched.
When the outside air temperature is low, the
heating effect may not be sufficient.
A small amount of refrigerant continues to flow
into the indoor unit even though it is not
operating.
These models are equipped with an auto restart
function. When the main power is turned off
without stopping the air conditioner with the
remote controller and is turned on again, the air
conditioner will start operation automatically in
the same mode as the one set with the remote
controller just before the shutoff of the main
power.
Even if the above items are checked, when the air conditioner does not
recover from the trouble, stop using the air conditioner and consult your
dealer.
In the following cases, stop using the air conditioner and consult your dealer.
When water leaks or drops from the indoor unit.
When the left operation indicator lamp blinks.
When the breaker trips frequently.
The remote control signal may not be received in a room where an electronic
ON/OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.
Operation of the air conditioner may interfere with radio or TV reception in
areas where the reception is weak. An amplifier may be required for the affected
device.
When thunder is heard, stop operation and disconnect the power supply plug
or turn off the breaker. Otherwise, the electrical parts may be damaged.
SG79Y404H03 6/14/06, 10:14 AM13
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mitsubishi MSZ-GA25VA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mitsubishi MSZ-GA25VA in the language / languages: English as an attachment in your email.

The manual is 1,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info