684504
13
Zoom out
Zoom in
Previous page
1/22
Next page
For the convenience of maintenance and debug, query function is
available by Press 2 buttons together: ” + , then
system running parameters will be shown one by one with following
sequence by each pushing of or button.
10
Installation & Owner's Manual
Fig.4-4
Fig.4-5
Fig.4-6
NOTE
While the ambient temperature below than -7, heat pump
efficiency will decrease dramatically, the unit will automatically
shift to E-heater running.
4.2.3 Basic function
Weekly disinfect function
unit disinfection unit immediately starts to heat water up to 65 to
kill the potential legionella bacteria inside water of tank,“ ”icon
will lighted on the display screen during disinfection; unit will quit
disinfection if water temperature is higher than 65 and
extinguish “ ”icon.
Vacation function
After pressing "Vaction" button, Unit will automatically heat water
to 15 for the purpose of energy saving during vacation days.
How is the unit running
If unit is OFF->press ->unit will be unlocked->press
to set target water temperature(38-60)->press ->unit
will automatically select heat source and start to heat water to
target temperature.
ON/O F F
1)
2)
3)
4.2.4 Query function
Table.4-2
No.
Hour
low bit
Min.
high bit
Min.
Low bit
Temp./
Dasys
Explenation
11 Software number
6 Temp. Th
5 Temp. TP
4 Temp. T4
3 Temp. T3
8 Last error code
9
Previous 1st error or
protection code
10
Previous 2nd t error or
protection code
7 Current Compressor
1 Temp. T5U
2 Temp. T5L
1000
1500
2000
2500
3000
3500
4000
4500
-25 -15 -5 5 15 25 35 45
Ambient temperature()
Capacity within Different Temperature
15 - 45
15 - 50
15 - 55
15 - 60
0
1
2
3
4
5
6
7
8
9
-25 -15 -5 5 15 25 35 45
Ambient temperature()
Heat Up Time within Different Temperature
15 - 45
15 - 50
15 - 55
15 - 60
0.00
1.00
2.00
3.00
4.00
5.00
6.00
-25 -15 -5 5 15 25 35 45
Ambient temperature()
COP within Different Temperature
15 - 45
15 - 50
15 - 55
15 - 60
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea RSJ-35 - 300RDN3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea RSJ-35 - 300RDN3 in the language / languages: English as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea RSJ-35 - 300RDN3

Midea RSJ-35 - 300RDN3 User Manual - Dutch - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info