INSTALLATION INSTRUCTIONS
When the declivity of the drain pipe downwards
is over 1/100, there should not be any winding.
The total length of the drain pipe when pulled
out traversely shall not exceed 20m, when the
pipe is over long, a prop stand must be installed
to prevent winding.
Refer to the figures on the right for the
installation of the pipes.
1.5m~2m
Insulating
material
Downward declivity
lower than 1/100
Bend
S shape
VP30
Downward declivity
lower than 1/100
Put as deep as possible
(about 10cm)
Fig.50-9
Fig.50-10
Drainage test
Check whether the drain pipe is
unhindered.
New built house should have this test
done before paving the ceiling.
5.6 Wiring(Console)
CAUTION
The appliance shall be installed in accordance
with national wiring regualtions.
The air conditioner should use separate power
supply with rated voltage.
The external power supply to the air conditioner
should have ground wiring, which is linked to the
ground wiring of the indoor and outdoor unit.
The wiring work should be done by qualified
persons according to circuit drawing.
An all-pole disconnection device which has at
least 3mm separation distance in all pole and
a residual current device(RCD)with the rating
of above 10mA shall be incorporated in the fixed
wiring according to the national rule.
Be sure to locate the power wiring and the
signal wring well to avoid cross-disturbance.
Do not turn on the power until you have
checked carefully after wiring.
5.6.1 Connect the cable
The installation bearer of sensing
device rotated to another side, and then
takes off cover of electrical box. (Take
off the electrical box if the capacity is
18000btu/h as well as using network
function.) (Refer to Fig.50-10)
Installation bearer
of sensing device
All the pictures in this manual are for
explanation purpose only. They may be
slightly different from the air conditioner
you purchased(depend on model). The
actual shape shall prevail.
NOTE:
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midea 2M-53K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midea 2M-53K in the language / languages: English as an attachment in your email.

The manual is 10,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Midea 2M-53K

Midea 2M-53K User Manual - English - 33 pages

Midea 2M-53K Installation Guide - German - 39 pages

Midea 2M-53K User Manual - German - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info