4.1 Appendix A: Technical Speci cations
Processing
Input Processing Channels 32 Input Channels, 8 Aux
Channels, 8 FX Return Channels
Output Processing Channels 8 / 16
16 aux buses, 6 matrices, 100
main LRC
Internal E ects Engines 8 / 16
(True Stereo / Mono)
Internal Show Automation 500 / 100
(structured Cues / Snippets)
Internal Total Recall Scenes 100
(incl. Preampli ers and Faders)
Signal Processing 40-Bit Floating Point
A/D Conversion 24-Bit, 114 dB Dynamic Range,
(8-channel, 96 kHz ready) A-weighted*
D/A Conversion 24-Bit, 120 dB Dynamic Range,
(stereo, 96 kHz ready) A-weighted*
I/O Latency (Console Input to Output) 0.8 ms
Network Latency (Stage Box In >
Console > Stage Box Out) 1.1 ms
Connectors
MIDAS PRO Series Microphone 16
Preampli er (XLR)
Talkback Microphone Input (XLR) 1
RCA Inputs / Outputs 2 / 2
XLR Outputs 8
Monitoring Outputs 2/2
(XLR / ¼" TRS Balanced)
Aux Inputs/Outputs 6/ 6
" TRS Balanced)
Phones Output (¼" TRS) 1 (Stereo)
AES50 Ports (KLARK TEKNIK SuperMAC) 2
Expansion Card Interface 32 Channel Audio Input / Output
ULTRANET P-16 Connector 1
(No Power Supplied)
MIDI Inputs / Outputs 1 / 1
USB Type A 1
(Audio and Data Import / Export)
USB Type B, rear panel, 1
for remote control
Ethernet, RJ45, rear panel, 1
for remote control
Mic Input Characteristics
Design MIDAS PRO Series
THD+N (0 dB gain, 0 dBu output) < 0.01% unweighted
THD+N (+40 dB gain, 0 dBu to < 0.03% unweighted
+20 dBu output)
Input Impedance 10 kΩ / 10 kΩ
(Unbalanced / Balanced)
Non-Clip Maximum Input Level +23 dBu
Phantom Power (Switchable per Input) +48 V
Equivalent Input Noise -125 dBu 22
@ +45 dB gain (150 Ω source) Hz-22 kHz, unweighted
CMRR @ Unity Gain (Typical) > 70 dB
CMRR @ 40 dB Gain (Typical) > 90 dB
Input/Output Characteristics
Frequency Response @ 0 dB to -1 dB 20 Hz – 20 kHz
48 kHz Sample Rate
Dynamic Range, 106 dB 22 Hz - 22 kHz,
Analogue In to Analogue Out unweighted
A/D Dynamic Range, 109 dB 22 Hz - 22 kHz,
Preampli er and Converter (Typical) unweighted
D/A Dynamic Range, 109 dB 22 Hz - 22 kHz,
Converter and Output (Typical) unweighted
Crosstalk Rejection @ 100 dB
1 kHz, Adjacent Channels
Output level, XLR Connectors +4 dBu / +21 dBu
(Nominal / Maximum)
Output Impedance, XLR Connectors 50 Ω / 50 Ω
(Unbalanced / Balanced)
Input impedance, TRS Connectors 20 kΩ / 40 kΩ
(Unbalanced / Balanced)
Non-Clip Maximum Input +21 dBu
Level, TRS Connectors
Output Level, TRS +4 dBu / +21 dBu
(Nominal / Maximum)
Output Impedance, 50 Ω / 50 Ω
TRS (Unbalanced / Balanced)
Phones Output Impedance / 40 Ω / +21 dBu (Stereo)
Maximum output Level
Residual Noise Level, -85 dBu 22 Hz-22 kHz,
Out 1-16 XLR Connectors, Unity Gain unweighted
Residual Noise Level, -88 dBu 22 Hz-22 kHz,
Out 1-16 XLR Connectors, Muted unweighted
Residual Noise Level, -83 dBu 22 Hz-22 kHz,
TRS and Monitor out XLR Connectors unweighted
Display
Main Screen 5" TFT LCD, 800 x 480
Resolution, 262k Colours
Channel LCD Screen 128 x 64 LCD with
RGB Colour Backlight
Main Meter 18 Segment (-45 dB to Clip)
Power
Switch-Mode Power Supply Auto-Ranging 100-240 VAC
(50/60 Hz) ± 10%
Power Consumption 70 W
Physical
Standard Operating 5°C – 40°C (41°F – 104°F)
Temperature Range
Dimensions 478 x 617 x 208 mm
(18.8 x 24.3 x 8.2")
Weight 14.3 kg (31.5 lbs)
* A-weighted figures are typically ~3 dB better
4.2 Appendix B: MIDI Operation
MIDI RX > Scenes
Whenever Program Change messages in the range 1-100 are received on
MIDI CH01, thecorresponding scene of the M32 internal show memory will
be loaded.
This requires the following preconditions:
SETUP / remote
MIDI In/Out check marks must be set according to the connection on
which MIDI input will be accepted (via physical MIDI connectors on M32
or S16, or via DN32-USB card)
MIDI In/Out check mark must be set for “Enable MIDI Scene Recall.
SETUP / global
When tick mark “Con rm Pop-Ups” / “Scene Load” is active, MIDI scene
recalls will only become active after manual con rmation
If you prefer activating scenes via MIDI Program Changes immediately,
un-check the “Con rmPop-Ups” / “Scene Load” tick mark.
SHOW CONTROL VIEW / home
Valid scenes must be stored in the internal M32 show  le. It is not
possible to recall emptyscenes
The scope of changes applied by a MIDI scene recall depends on the
Scene Safes, ParameterSafes and Channel Safes settings, same as with
recalling the scene locally.
MIDI TX > Scenes
Every scene can be assigned one speci c MIDI command/event. Each time the
scene is loaded the MIDI command will be sent out once. Possible choices for MIDI
commands/events to be found on Scenes View/MIDI page:
O > no message will be sent upon scene load
Program Change > select the MIDI Channel and the Program Number
(using knobs 4/5 at the main display)
Control Change > select the MIDI Channel, Controller number and
value(using knobs 4-6 at the main display)
Note > select the MIDI Channel, Note number and velocity(using knobs
4-6 at the maindisplay).
Will send out a Note On command directly followed by the same
Note O command.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Midas M32R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Midas M32R in the language / languages: English as an attachment in your email.

The manual is 29,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info